2.6 Electrical connection

• Connect the boiler to the fused (3 amp) switch spur unit
adjacent to boiler.
• The switch unit must always be accessible.
When the switch spur is on the following components of this
230 V
appliance can be live (230 V):
• electrical connection pump;
• electrical connection gas combination block;
• electrical connection three-way valve;
• most parts of the control unit;
• ignition transformer;
• X1, X2, X4, X5, X6 and X7 terminal strip;
• 230 V supply cable connection.
LT.AL.W7H.000.022
2.6.1 The control unit
The Remeha Avanta Plus has an electronic regulation and
control unit with an integrated ionisation flame detector. The
heart of the boiler control unit is a microprocessor, the 'abc
,
®'
which controls and protects the boiler.
The boiler is not phase sensitive. The maximum rated input is
between 115 and 180 W (depending on boiler type).
The boiler is fully pre-wired internally, all external connections
can be made using the terminal strips X5 - X7 - X9 and 230
V input (X2 terminal). See the diagram for the position of the
connectors and fuse (F2) on the control unit.
The most important properties of the control unit are summa-
rized in table 04.