6 ENABLING THE BOILER

R000176-A
LT.AL.W7H.000.225
LT.AL.W7H.000.212
126582-160412
• Check the boiler water pressure. If the water pressure is less than 1 bar, the sys-
tem has to be topped up with water.
• Switch on the boiler at the fused spur unit; the boiler will run the start-up program.
230 V
- A display test will briefly appear showing all segments of the display.
fK[xx software version
pK[xx parameter version;
- A venting cycle of 3 minutes now follows, the version numbers will be displayed
alternately.
- Next, the following will appear in the display:
K1 pre-purge stage
K2 ignition stage
K3 operating in CH mode or
K4 operating in DHW mode
K7 pump run on after CH or DHW is satisfied
K0 stand-by mode
• Set the room thermostat to the desired room temperature.
The boiler will now automatically start operating.
6. Enabling the boiler