Area Arming Options (Address 2650-2657); Remote Access Logging (Address 3184) - NAPCO x255 Programming Instructions Manual

Table of Contents

Advertisement

Page 48
AREA ARMING OPTI ONS (ADDRE SS 2650-2 657)
ARMING
AREA
PRIORITY AREA ARMING:
1. Select the desired arming area.
2. Enter the corresponding Area number in each the address location, in Binary (Bit) Format. NOTE: See Direct Address
Programming Example on page 15.
U
D
3. Press
or
to save.
NOTE: Dark shaded data value box shows option not available.
REMOTE ACCESS LOGGING: Enable logging of every keypad access event.
1.
Select the desired option entering the option number (1-8) for each digit.
2.
Enter corresponding option number in address location.
U
D
3.
Press
or
to save.
X
GEM-X255 Programming Instructions
ADDR
A1
A2
1
2
1
2650
2
2651
3
2652
4
2653
5
2654
6
2655
7
2656
8
2657
[Default = blank (•) blank (•) from address 2650-2657]
REMOTE ACCES S L OGGIN G (AD DRESS 3184)
3184 System Options - Enable Keypad
Default
Option
OFF
1
2
OFF
OFF
3
4
OFF
OFF
5
OFF
6
OFF
7
OFF
8
PRIORITY AREA ARMING
A3
A4
A5
A6
3
4
5
6
Enable Keypad 1
Enable Keypad 2
Enable Keypad 3
Enable Keypad 4
Enable Keypad 5
Enable Keypad 6
Enable Keypad 7
Enable Keypad 8
WI1092E 10/05
A7
A8
7
8
L
NAPCO Security Systems

Advertisement

Table of Contents
loading

Table of Contents