NAPCO x255 Programming Instructions Manual page 61

Table of Contents

Advertisement

WI1092E 10/05
New
Compat #
EZM Address
Workbook) similar to its keypad address. If no other EZMs are to be used, designate the keypad as Group "01" at the
EZM ADDRESS 00
"
" display. In multiple-EZM systems, enter an assigned group number "01" through "22". (Each EZM
must have a unique assigned group number, starting with "01" and proceeding consecutively.) Press the
to continue or press the
Zone Response
2. Add up the circled numbers.
3. At the keypad, enter the sum as a two-digit number "01" through "15" on the display, then press
Example. Change Zones 2, 3 and 4 to 50mS response.
1. Circle numbers for Zones 2, 3 and 4: (2), (4) and (8).
2. Add up the circled numbers: 2 + 4 + 8 = 14.
3. Enter "14" at the keypad, then press the
Press the
button to continue or press the
R
Program Control
Message #
gram control messages can be selected (0-6) as displayed in the following table:
Program Control Message
0
(No Message)
1
**Enter Now**
2
Door Control
3
Gate Control
4
Light Control
5
Control #1
6
Control #2
1. Enter a message number
U
2. Press
to save.
3. Press the
R
button to exit the Keypad Configuration Mode (display will read "
C
4. Replace Jumper JP1 across Pins 1–2 (top two).
L
NAPCO Security Systems
Compatibility Number
A 4-digit Compatibility Number, if programmed, will restrict this keypad to
0000
work on a panel programmed with a matching number.
1. Enter a 4-digit number
2. Press
C
EZM Address
The keypad's internal EZM (Expansion Zone Module) may be utilized to
01
provide four additional wired zones. Whether used alone or in conjunction
with optional GEM-EZM series modules or other keypad EZMs, it must be
assigned a unique address (or Group number, see Keypad Programming
button to exit.
C
Zone Response
The normal loop response of each keypad expansion zone is 750mS, how-
00
ever the response time of any zone can be reduced to 50mS as follows.
1. Of the following, circle the number(s) in parentheses associated with the
zone(s) to be changed: Zone 1=(1); Zone 2=(2); Zone 3=(4); Zone 4=(8)
U
button.
C
Program Control Message
A code-keypad association can be programmed such that when the code is
?
entered at a specific keypad, a PGM Lug will be activated for 7 seconds,
and a selected message will be displayed on this keypad. Six different pro-
button to continue (the display will loop back through selections, for changes) or press the
U
to save. Press the
button to exit.
button to exit.
X
GEM-X255 Programming Instructions
button to continue or press the
R
U
.
01 OUT OF SYSTEM
").
Page 61
button
R

Advertisement

Table of Contents
loading

Table of Contents