Ezm Group & Area Arming Opt. (Addr 0737-0744) - NAPCO Gemini GEM-P816 Programming Instructions Manual

Table of Contents

Advertisement

WI995C 2/04
EZM Group 1
EZM Group 2
ADDRESS 0737
ADDRESS 0738
Default depends on Easy Menu Question "
will be automatically enabled. If 32 Zones are used and Zone Doubling is enabled, then only Groups 1-4 will be automatically enabled.
EZM TYPE
EZM
GROUP
DATA
1
ENTRIES
OPTION
2
Not used
blank (•)
(No EZM
1
4-Zone EZM
AREA ARMING OPTI ON S (ADD RESS 0743 & 0744)
Priority
ADDRESS
Arming
0743
Area 1
[Default = blank (•)]
PRIORITY ARMING/AREA 1
DATA ENTRIES
blank (•)
1
L
NAPCO Security Systems
EZM GROUP OP TIONS (ADDRES S 0737-0742)
# OF ZNS IN AREA 1 ENTER # ZONES
ZONES COVERED
EZM GROUP OPTIONS: Up to 2 Groups of 4 Zones each may be programmed
NORMAL
depending on the number of Zones used and which EZM modules are con-
9-12
nected. Each Group represents 4 Zones.
13-16
!
1. Select EZM type from the table shown.
!
2. Enter either blank (•) or "1" in corresponding address locations above.
NOTE: Dark shaded data value box shows option not available.
!
3. Press
PRIORITY AREA ARMING:
!
1.
Select option from the table shown.
!
2.
Enter either blank() or "1" in corresponding address location.
NOTE: Dark shaded data value box shows option not available.
OPTION
!
3.
Press
Not Used
Enabled
". For example, if 32 Zones are used and Zone Doubling is not enabled, then all 6 Groups
U
D
or
to save.
U
D
or
to save.
X
GEM-P816 Programming Instructions
!
Page 23