External Relay Control / Relays - NAPCO x255 Programming Instructions Manual

Table of Contents

Advertisement

WI1092E 10/05
EXTERNAL REL AY CONTR OL / R ELAYS 79-9 6
(RELAY/entry 79)
ADDRESS 3856 & 3112-3115
3856
3112
3113
L
R
L
R
L
(RELAY/entry 82)
ADDRESS 3859 & 3124-3127
3859
3124
3125
L
R
L
R
L
(RELAY/entry 85)
ADDRESS 3862 & 3136-3139
3862
3136
3137
L
R
L
R
L
(RELAY/entry 88)
ADDRESS 3865 & 3148-3151
3865
3148
3149
L
R
L
R
L
(RELAY/entry 91)
ADDRESS 3868 & 3160-3163
3868
3160
3161
L
R
L
R
L
(RELAY/entry 94)
ADDRESS 3871 & 3172-3175
3871
3172
3173
L
R
L
R
L
[Default = blank (•) blank (•) from address 3778-3873 & 2800-3183]
To program, follow the 5 steps below:
STEP 1: RELAY # OPTIONS:
96 available external relays from Relay Module RM3008. Multiple entries can
drive the same External Relay.
Select the relay number from Table 1 (shown on next page); enter in
corresponding left and right digit address locations.
Note: Entries 01-96 correspond to relays 1 through 96. If entries are zero, zero
(00), then relay number is identical to the relay/entry address table number, in
the selected address table(s) above.
STEP 2: AREA OPTIONS:
Each relay/entry can be assigned to Area 1-8 or all areas.
Select the area from Table 2 (shown on next page); enter in corresponding left and right digit
address locations.
STEP 3: TIMEOUTS:
Each relay event can be assigned a timeout depending on Alarm Type option.
If Alarm Type is selected for timeout in minutes or seconds, enter the 3-digit timeout duration in corre-
sponding address location. To choose seconds or minutes, see step 5A below. 254 is maximum entry.
STEP 4: EVENT ID CODES:
Select 2-digit Event ID from Table 4 (see page 55); enter in corresponding address locations (left and right digit).
STEP 5: RELAY EVENT CONDITION OPTIONS:
condition; also, select a timeout type for each.
5A. Select Alarm Type and Timeout Type from Table 5A (see page 56); enter in corresponding address location (left digit).
NOTE: Select Timeout from Step 3.
5B. Select Activation from from Table 5B (see page 56); enter in corresponding address location (right digit).
L
NAPCO Security Systems
ADDRESS 3857 & 3116-3119
3114
3115
3857
3116
R
L
R
L
R
L
R
ADDRESS 3860 & 3128-3131
3126
3127
3860
3128
R
L
R
L
R
L
R
ADDRESS 3863 & 3140-3143
3138
3139
3863
3140
R
L
R
L
R
L
R
ADDRESS 3866 & 3152-3155
3150
3151
3866
3152
R
L
R
L
R
L
R
ADDRESS 3869 & 3164-3167
3162
3163
3869
3164
R
L
R
L
R
L
R
ADDRESS 3872 & 3176-3179
3174
3175
3872
3176
R
L
R
L
R
L
R
Each relay/entry can be assigned to any of the
Each relay event can be assigned any of the available event IDs from the table.
Each relay event can be assigned an alarm type; and an activation
(ADDRESS 3856-3873 & 3112-3183)
(RELAY/entry 80)
3117
3118
3119
3858
L
R
L
R
L
(RELAY/entry 83)
3129
3130
3131
3861
L
R
L
R
L
(RELAY/entry 86)
3141
3142
3143
3864
L
R
L
R
L
(RELAY entry 89)
3153
3154
3155
3867
L
R
L
R
L
(RELAY/entry 92)
3165
3166
3167
3870
L
R
L
R
L
(RELAY/entry 95)
3873
3177
3178
3179
L
L
R
L
R
RELAY # AREA
L
R
(•)
Step
1
X
GEM-X255 Programming Instructions
Page 53
(RELAY/entry 81)
ADDRESS 3858 & 3120-3123
3120
3121
3122
R
L
R
L
R
(RELAY/entry 84)
ADDRESS 3861 & 3132-3135
3132
3133
3134
R
L
R
L
R
(RELAY/entry 87)
ADDRESS 3864 & 3144-3147
3144
3145
3146
R
L
R
L
R
(RELAY/entry 90)
ADDRESS 3867 & 3156-3159
3156
3157
3158
R
L
R
L
R
(RELAY/entry 93)
ADDRESS 3870 & 3168-3171
3168
3169
3170
R
L
R
L
R
(RELAY/entry 96)
ADDRESS 3873 & 3180-3183
3180
3181
3182
R
L
R
L
R
RELAY EVENT OPTIONS
Timeout
Event ID COND.
L
R
L
R
(•)
Step
Step
Step
2
3
4
Continued
3123
L
R
3135
L
R
3147
L
R
3159
L
R
3171
L
R
3183
L
R
L
R
Step
5

Advertisement

Table of Contents
loading

Table of Contents