Area Output Control Options (Address 2700-2739) - NAPCO x255 Programming Instructions Manual

Table of Contents

Advertisement

WI1092E 10/05
AREA OUT PUT C ONTR OL OP TI ON S (ADDRES S 2700-2739)
DISARMING AREA 1 TURNS OFF AREA OUTPUT
OUTPUT SILENCED
ADDR
A1
(TURNED OFF)
1
Burglary Output
2700
ON
Pulsed Burg. Output
2708
ON
Fire Output
2716
Reset Relay
2724
Auxiliary Relay
2732
[Default = Noted above with "ON"]
DISARMING AREA 3 TURNS OFF AREA OUTPUT
OUTPUT SILENCED
ADDR
A1
(TURNED OFF)
1
Burglary Output
2702
Pulsed Burg. Output
2710
Fire Output
2718
Reset Relay
2726
Auxiliary Relay
2734
[Default = blank (•) blank (•) from address 2702-2735]
DISARMING AREA 5 TURNS OFF AREA OUTPUT
OUTPUT SILENCED
ADDR
A1
(TURNED OFF)
1
Burglary Output
2704
Pulsed Burg. Output
2712
Fire Output
2720
Reset Relay
2728
Auxiliary Relay
2736
[Default = blank (•) blank (•) from address 2704-2737]
DISARMING AREA 7 TURNS OFF AREA OUTPUT
OUTPUT SILENCED
ADDR
A1
(TURNED OFF)
1
Burglary Output
2706
Pulsed Burg. Output
2714
Fire Output
2722
Reset Relay
2730
Auxiliary Relay
2738
AREA OUTPUT TURNS OFF UPON DISARM: Select options for any of the 5 Outputs per area when disarming a particular area.
1. Select the desired option.
2. Enter the corresponding Area number in each the address location, in Binary (Bit) Format. NOTE: See Direct Address
Programming Example on page 15.
U
D
3. Press
or
to save.
L
NAPCO Security Systems
A2
A3
A4
A5
A6
A7
2
3
4
5
6
7
ON
ON
A2
A3
A4
A5
A6
A7
2
3
4
5
6
7
A2
A3
A4
A5
A6
A7
2
3
4
5
6
7
A2
A3
A4
A5
A6
A7
2
3
4
5
6
7
OUTPUT SILENCED
A8
ADDR
(TURNED OFF)
8
Burglary Output
2701
Pulsed Burg. Output
2709
Fire Output
2717
Reset Relay
2725
Auxiliary Relay
2733
[Default = Noted above with "ON"]
OUTPUT SILENCED
A8
ADDR
(TURNED OFF)
8
Burglary Output
2703
Pulsed Burg. Output
2711
Fire Output
2719
Reset Relay
2727
Auxiliary Relay
2735
[Default = blank (•) blank (•) from address 2702-2735]
OUTPUT SILENCED
A8
ADDR
(TURNED OFF)
8
Burglary Output
2705
Pulsed Burg. Output
2713
Fire Output
2721
Reset Relay
2729
Auxiliary Relay
2737
[Default = blank (•) blank (•) from address 2704-2737]
OUTPUT SILENCED
A8
ADDR
(TURNED OFF)
8
Burglary Output
2707
Pulsed Burg. Output
2715
Fire Output
2723
Reset Relay
2731
Auxiliary Relay
2739
X
GEM-X255 Programming Instructions
Page 49
DISARMING AREA 2 TURNS OFF AREA OUTPUT
A1
A2
A3
A4
A5
A6
1
2
3
4
5
6
ON
ON
ON
ON
DISARMING AREA 4 TURNS OFF AREA OUTPUT
A1
A2
A3
A4
A5
A6
1
2
3
4
5
6
DISARMING AREA 6 TURNS OFF AREA OUTPUT
A1
A2
A3
A4
A5
A6
1
2
3
4
5
6
DISARMING AREA 8 TURNS OFF AREA OUTPUT
A1
A2
A3
A4
A5
A6
1
2
3
4
5
6
A7
A8
7
8
A7
A8
7
8
A7
A8
7
8
A7
A8
7
8

Advertisement

Table of Contents
loading

Table of Contents