Zone Options / Zones 1-16 (Address 1200-1386) - NAPCO x255 Programming Instructions Manual

Table of Contents

Advertisement

WI1092E 10/05
ZON E O PTI ONS / ZONE S 1- 1 6 (AD DRESS 12 0 0-1 3 86 )
ZONE OPTIONS
50ms Loop Response (A)
20ms Loop Response (A)
Priority
Priority with Bypass
Auto-Bypass
Selective Bypass
Keyswitch Arming
Auto-Bypass Re-entry
Pre-Alarm Warning
Never Arm
24-Hour Zone
Burg. Alarm Output
Pulsed Alarm Output
Fire Output (Lug E9)
Reset Relay
Auxiliary Relay
Entry/Exit 1
Entry/Exit 2
Exit/Entry Follower
Auto Reset
Swinger Shutdown
Chime
Abort Delay
Power-up Delay
Day Zone Open
Day Zone Short
Alarm on Day Zone
RPT Alarm Tel 1
RPT Alarm Restore Tel 1
RPT Trouble Tel 1
RPT Trouble Restore Tel 1
RPT Alarm Tel 3
RPT Alarm Restore Tel 3
RPT Trouble Tel 3
RPT Trouble Restore Tel 3
No EOL Resistor
Sensor Watch
Trouble on Open
Trouble on Short
Trouble on Night Open
Zone Area 1
Zone Area 2
Zone Area 3
Zone Area 4
Zone Area 5
Zone Area 6
Zone Area 7
Zone Area 8
2-Wire Smoke Detectors
(B)
Guard Tour Bypass
Zone ANDing Group 1
Zone ANDing Group 2
Zone ANDing Group 3
Zone ANDing Group 4
Zone ANDing Group 5
Zone ANDing Group 6
Zone ANDing Group 7
Zone ANDing Group 8
Interior #1 Bypass
Interior #2 Bypass
Keypad Sounder on Alarm
Fire (C)
Fire Alarm Verification (C)
Interior (STAY) Bypass
Chime 2
When the Easy Program Menu is used, these features are enabled by default (for new panels or after a Cold Start (address 4093)). Zone Area 1
is enabled for the first 8 zones only, by default.
Do not program if "K Series" keypads (with "
Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
In UL installations, all Fire Zones must also be programmed for "Pulse Burg Output Cadence" (Address 2422, press 1 (bit zero)).
L
NAPCO Security Systems
ZONES 1
ADDR Z1
Z2
Z3
Z4
1
2
3
4
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1275
1276
1284
1286
" and "
" buttons) are used in the system.
P
Q
8
Z5
Z6
Z7
Z8 ADDR Z9 Z10 Z11 Z12 Z13 Z14 Z15 Z16
5
6
7
8
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1375
1376
1384
1386
X
GEM-X255 Programming Instructions
Page 31
ZONES 9
16
1
2
3
4
5
6
See Zone Options on Page 37.