Ezm Group Options (Address 2555-2576) - NAPCO x255 Programming Instructions Manual

Table of Contents

Advertisement

WI1092E 10/05
EZM Group 1
EZM Group 2
ZONES 9-12
ZONES 13-16
ADDRESS 2555
ADDRESS 2556
EZM Group 7
EZM Group 8
ZONES 33-36
ZONES 37-40
ADDRESS 2561
ADDRESS 2562
EZM Group 13
EZM Group 14
ZONES 57-60
ZONES 61-64
ADDRESS 2567
ADDRESS 2568
EZM Group 19
EZM Group 20
ZONES 81-84
ZONES 85-88
ADDRESS 2573
ADDRESS 2574
NOTE: Zones 1-8 are included in the control panel and Zones 9-96 (Groups 1-22) are EZM Zones (either Wireless or Hardwired).
EZM TYPE
DATA
OPTION
ENTRIES
RIGHT
blank (•)
Not used (No
EZM present)
1
4-Zone EZM
EZM PGM TERMINAL CONTROL
GROUP
ADDR
A1
A2
A3
NUMBER
1
2
1
2577
2
2578
3
2579
4
2580
5
2581
6
2582
7
2583
8
2584
9
2585
10
2586
11
2587
[Default = blank (•) blank (•) from address 2577-2587]
EZM PGM ARMED TERMINAL CONTROL: For each zone group select the area(s) which, when armed, will activate the PGM Lug
on the corresponding EZM modules. Each zone group corresponds to 4 zones. If 8-Zone EZMs are used each one is treated as
TWO zone groups. NOTE: Lug goes ACTIVE (low) when ANY selected area is armed. When activated, the PGM Lug goes
negative (to Ground).
1. Select the desired group number.
2. Enter the corresponding Area number in each the address location, in Binary (Bit) Format. NOTE: See Direct Address
Programming Example on page 15.
U
D
3. Press
or
to save.
L
NAPCO Security Systems
EZM GR OUP OPTIONS (ADDRE S S 2555- 2576)
EZM Group 3
ZONES 17-20
ADDRESS 2557
EZM Group 9
ZONES 41-44
ADDRESS 2563
EZM Group 15
ZONES 64-68
ADDRESS 2569
EZM Group 21
ZONES 89-92
ADDRESS 2575
EZM GROUP OPTIONS: Up to 22 Groups of 4 Zones each may be programmed depending on the
number of zones used and which EZM modules are connected. Each group represents 4 zones.
1. Select EZM type from the table shown.
2. Enter either blank (•) or "1" in corresponding address locations above.
U
D
3. Press
or
to save
A4
A5
A6
A7
A8
3
4
5
6
7
8
EZM Group 4
EZM Group 5
ZONES 21-24
ZONES 25-28
ADDRESS 2558
ADDRESS 2559
EZM Group 10
EZM Group 11
ZONES 45-48
ZONES 49-52
ADDRESS 2564
ADDRESS 2565
EZM Group 16
EZM Group 17
ZONES 69-72
ZONES 73-76
ADDRESS 2570
ADDRESS 2571
EZM Group 22
Default depends on Easy Menu Question
"# OF ZNS IN AREA1
ZONES 93-96
and "# OF ZNS IN AREA2
ADDRESS 2576
. For example, If 96 zones are used, then all 22
groups will be automatically enabled. If only 8
zones are used, then groups 1-22 will be
automatically disabled.
EZM PGM TERMINAL CONTROL
GROUP
ADDR
A1
A2
NUMBER
1
2
12
2588
13
2589
14
2590
15
2591
16
2592
17
2593
18
2594
19
2595
20
2596
21
2597
22
2598
[Default = blank (•) blank (•) from address 2588-2598]
X
GEM-X255 Programming Instructions
Page 47
EZM Group 6
ZONES 29-32
ADDRESS 2560
EZM Group 12
ZONES 53-56
ADDRESS 2566
EZM Group 18
ZONES 77-80
ADDRESS 2572
A3
A4
A5
A6
A7
A8
3
4
5
6
7
8