SYST EM OPT ION S (AD DRES S 24 2 0-2 4 22, 387 4, 3 90 5)
2420 System Options
Option
Default
1
OFF
Disable System Trouble Audible (at Keypad)
OFF
2
3
OFF
Disable Code required for Func. Mode Lvl. 1
OFF
4
Disable Code required for EZ Bypass
OFF
5
Disable Keypad Instant Button
OFF
6
Enable Telephone Line-Fault Test
OFF
7
OFF
8
† NOTE: Not for UL Installations.
**
Default for this address contingent on EZ Menu selections.
2422 System Options
Option
Default
1
ON
Pulse Burg Output Cadence
OFF
2
Wireless Smoke Low Battery Resound
OFF
3
4
OFF
Enable Smoke Detector Dirty Trouble
OFF
5
OFF
6
Disable Exit/Entry Urgency Tone at Keypad
OFF
7
Select Bell Output on Keyfob Arming
OFF
8
Enable Burg. Output on Telco Fail only when Armed
§
In Zone Options, Fire Zones, and only Fire Zones,
must be programmed for pulse alarm output.
SYSTEM OPTIONS:
1.
Select the desired option entering the option
number (1-8) for each digit.
2.
Enter corresponding option number in address
location.
NOTE: Dark shaded data value box shows option not
U
available. Press
or
ALARM/TR OUBL E REPORTIN G C ODES (A DDRESS 3880-3881)
ALARM/TROUBLE
ADDRESS 3880-3881
REPORTING CODES
Wireless Supervisory
3880
Wireless Tamper
3881
[Default = blank (•) from address 3880-3881]
L
NAPCO Security Systems
Chime on Lug E4
Disable AC Fail Detection
Telco Fail only when Armed
§
Supervised Alarm Output
Disable Area Entry Relays
D
to save.
ALARM/TROUBLE REPORTING CODES:
1. Enter in corresponding address location (left and right digits).
NOTE: Left digit is the first digit and right digit is the second digit in a two digit CS receiver
format.
2. Valid entries are: 1-9, 0 and B-F.
NOTE: A is not permitted.
3. To disable a code leave boxes blank (•).
U
4. Press
or
System Options
2421
Option
Default
1
OFF
OFF
2
3
OFF
OFF
4
OFF
5
6
OFF
OFF
7
OFF
8
System Options
3874
Option
Default
1
OFF
OFF
2
OFF
3
4
OFF
OFF
5
6
OFF
ON
7
8
3905 System Options
Option
Default
OFF
1
OFF
2
3
OFF
OFF
4
OFF
5
OFF
6
OFF
7
OFF
8
Enable Ambush in User Assignment Code Type
**
Default for this addresses contingent on EZ Menu selections.
D
to save.
X
GEM-X255 Programming Instructions
Automatic Interior Bypass/Easy Exit
Veri-phone Zones trip Aux. Output
Veri-phone Zones Priority over Alarms
AuxOut Chirp on Keyfob Arm/Disarm**
Disable Auxout Clear on Disarm
2nd Call Answering Machine Override
Disable Zone Fault Scrolling (Auto Status)
Veri-phone Zones trip Fire Output
Enable GEM-PRINT
Enable Cancel Report to Telco 3
Wireless Trouble to Telco 1
Wireless Trouble to Telco 3
Enable Set Time/Date Message
RESERVED
Enable Keypad Time/Date Display
RESERVED
RESERVED
Enable Exit Delay Restart (SIA-FAR)**
Enable Bell on Exit Error**
Enable Report Exit Err/Recent Close**
Digital Dialer Rpt Enter/Exit Test Mode**
Enable CP-01 Limits**
Disable Call Waiting on First Attempt