PCI Board Status LED Indications
LED
Description
indications
Green
Duplex is specified,
however, the server
works in simplex
mode.
Off
The PCI board is
properly installed and
operating in
non-duplex mode.
(Does not depend on
simplex or duplex
mode.)
The PCI board is
properly installed and
duplex is configured.
The PCI board is not
installed yet, the PCI
board is installed
incorrectly, or the
power is not supplied.
Red
In the process of
configuring or
canceling the duplex
mode.
Although the PCI
board is mounted, it is
offline or not
functioning.
Action
Configure duplex.
Reapply the driver.
In non-duplex mode, no specific problem occurs.
The system is operating normally in duplex mode.
Mount the PCI board correctly.
If the PCI board was not mounted, there is no
problem.
Check the condition of power unit.
Remount the PCI module.
Wait for a while until the indication changes. If the
indication does not change, check the status of the
installed PCI board slot using NEC ESMPRO
Manager.
Make the installed PCI board slot online from NEC
ESMPRO Manager.
Mount the PCI board correctly.
8-49