NEC Express 5800/320Lb-R User Manual page 208

Nec servers user's guide
Table of Contents

Advertisement

7-4
STATUS LED
Indication
Color State
= A =
AmbientTempAlm
Amber Blink CPU module
00
AmbientTempAlm
Amber
02
AmbientTempAlm
Amber Blink CPU module
07
AmbientTempAlm
Amber
09
= B =
BMC Unsync
-
BMC0 Not Ready Green Blink PCI module #1
BMC1 Not Ready Green Blink PCI module #2
= C =
Cor0 +12vAlm 00 Amber Blink PCI module #1
Cor0 +12vAlm 02 Amber
Cor0 +12vAlm 07 Amber Blink PCI module #1
Cor0 +12vAlm 09 Amber
Cor0 +2.5vAlm
Amber Blink PCI module #1
00
Cor0 +2.5vAlm
Amber
02
Cor0 +2.5vAlm
Amber Blink PCI module #1
07
Cor0 +2.5vAlm
Amber
09
Cor0 +3.3vAlm
Amber Blink PCI module #1
00
Cor0 +3.3vAlm
Amber
02
Cor0 +3.3vAlm
Amber Blink PCI module #1
07
Cor0 +3.3vAlm
Amber
09
Cor0 +3.3vsAlm
Amber Blink PCI module #1
00
Cor0 +3.3vsAlm
Amber
02
Cor0 +3.3vsAlm
Amber Blink PCI module #1
07
Cor0 +3.3vsAlm
Amber
09
Cor0 +5.0vAlm
Amber Blink PCI module #1
00
Cor0 +5.0vAlm
Amber
02
Cor0 +5.0vAlm
Amber Blink PCI module #1
07
Suspected
module
Temperature alarm (lower
limit)
Lit
CPU module
Fatal temperature alarm
(lower limit)
Temperature alarm (upper
limit)
Lit
CPU module
Fatal temperature alarm
(upper limit)
-
PCI module #1
The BMC cannot be
synchronized.
PCI module's BMC is
disconnected
12-V power voltage alarm
(lower limit)
Lit
PCI module #1
Fatal 12-V power voltage
alarm (lower limit)
12-V power voltage alarm
(upper limit)
Lit
PCI module #1
Fatal 12-V power voltage
alarm (upper limit)
2.5-V power voltage alarm
(lower limit)
Fatal 2.5-V power voltage
Lit
PCI module #1
alarm (lower limit)
2.5-V power voltage alarm
(upper limit)
Fatal 2.5-V power voltage
Lit
PCI module #1
alarm (upper limit)
3.3-V power voltage alarm
(lower limit)
Fatal 3.3-V power voltage
Lit
PCI module #1
alarm (lower limit)
3.3-V power voltage alarm
(upper limit)
Fatal 3.3-V power voltage
Lit
PCI module #1
alarm (upper limit)
3.3-V power voltage alarm
(lower limit)
Fatal 3.3-V power voltage
Lit
PCI module #1
alarm (lower limit)
3.3-V power voltage alarm
(upper limit)
Fatal 3.3-V power voltage
Lit
PCI module #1
alarm (upper limit)
5-V power voltage alarm
(lower limit)
Fatal 5-V power voltage alarm
Lit
PCI module #1
(lower limit)
5-V power voltage alarm
(upper limit)
Explanation
Contact your sales agent.
Contact your sales agent.
If disconnection continues
for a while, contact your
sales agent.
Contact your sales agent.