System And Partial Failure Analysis Overview; Failure Analysis For Ip8800/S6700, Ip8800/S6600, And Ip8800/S6300 - NEC IP8800/S2400 Series Troubleshooting Manual

Nec electronics america network hardware user manual
Table of Contents

Advertisement

1.2

System and Partial Failure Analysis Overview

1.2.1
Failure Analysis for IP8800/S6700, IP8800/S6600, and IP8800/
S6300
If a failure occurs during operation and the system can be visually and directly checked, follow the procedure in
"2.1 Troubleshooting for IP8800/S6700, IP8800/S6600, and
The device status is displayed on the basic control unit (BCU) for IP8800/S6700, the control and switching unit (CSU)
for IP8800/S6600, and management and switching unit (MSU) for IP8800/S6300. LED display of BCS/CSU/MSU is
shown in the
"Table 1-1: LED Indications, Switches, and
1-1: Example of Front Panel
For LEDs of optional components other than BCU/CSU/MSU shown as an example (BSU, NIF, power supply, and fan
unit) and the layout of front panel other than
Installation Guide."
Even though the system cannot be visually and directly checked, troubleshooting can be performed similarly by
checking system LEDs using the operation command from the remote operation terminal.
Table 1-1: LED Indications, Switches, and Connectors
No.
Name
1
STATUS
LED: Green/Orange/
Red
2
SYSTEM
LCD and operation key
OPERATION
PANEL
3
ACC
LED: Green
4
SD CARD
Connector
5
RESET
Switch
(Non-locked)
6
ACH
Switch
(Non-locked)
7
ACTIVE
LED: Green
8
SYSTEM1
LED: Green/Orange/
Red
Layout."
"Figure 1-1: Example of Front Panel
Type
Status
Operation status of BCU/
CSU/MSU
System operation panel
Memory card status
SD card slot
System manual reset
switch
BCU/CSU/MSU
switchover switch
BCU/CSU/MSU operation
status
System status
IP8800/S6300" to troubleshoot.
Connectors." Also, Front panel layout is shown in the
Layout," see the manual "Hardware
Lit in green: Operational
Lit in orange: Self-diagnosis in progress
Blinking in green: Loading software
Lit in red: Failure detected
OFF: Power is OFF (BCU/CSU/MSU replaceable)
Displays the device information, operation
instructions, and failure information (for details, see
the manual "Configuration Settings")
Lit in green: Accessing the memory card (never detach
it).
OFF: Memory card in idle state (memory card setting/
removal permitted)
SD card slot
Pressing and holding for a second
: When the system fails
Pressing and holding for 5 seconds
: When the password is forgotten
When BCU/CSU/MSU is redundant, switchover
between the active system and standby system is
.
performed
*2*5
Lit in green: Active system
OFF: Standby system
Lit in green: Operational
Lit in orange: System partial failure detected
Lit in red: System failure detected
1.
Overview
"Figure
Description
*1
*2*3
*2*4
3