No.
Troubleshooting Steps
3
According to the failure
statistical information displayed
by the show interfaces
command, check to see if the
statistical information below is
counted for the port. If counted,
see "Problem" and "Action"
columns. [IP8800/S6700]
[IP8800/S6600] [IP8800/
S6300]
• RF
4
According to the failure
statistical information displayed
by the show interfaces
command, check to see if the
statistical information below is
counted for the port.
If counted, see "Problem" and
"Action" columns.
• Long frames
5
Check to see if statistics in the
following is not counted by the
show qos queueing
command. If it is counted, see
"Problem" and "Action"
columns.
• discard_pkt
3.4.6

Communication Failure on Using PoE

If electricity is not provided when PoE is in use, isolate the problem using the failure analysis methods listed in the
following table.
Table 3-12: Communication Failure Analysis Methods When PoE Is in Use
No.
Troubleshooting Steps and Command
1
Check to see PoEStatus display on the port by
the show power inline command.
2
Check to see if the port is shutdown.
Problem
Line quality on
Check the type of fiber optics. For the fiber optics type, see "Hardware
sending side is
Installation Guide."
degraded.
Check the attenuation value if an optical attenuator is used. For the
optical level, see "Hardware Installation Guide."
Check the cable length. For the cable length, see "Hardware Installation
Guide."
Check to see if the cable is connected correctly. Check to see if end
surfaces of the cable are dirty. If they are dirty, remove the dirt.
Check to see if the transceiver is connected correctly.
For the transceiver, follow the segment standard on the remote system.
Check to see if the optical level is correct. For the optical level, see
"Hardware Installation Guide."
Perform the line test on this system and confirm that there is no problem
in the sending function. See the execution results of the no test
interfaces command and follow the indicated actions. For the test
type to be specified, see
Packets with
Follow the jumbo frame setting on the remote system.
invalid frame
length are received.
Packets are being
Review the system maintenance using discard control and shaper.
discarded.
• PoEStatus indicates off
Electricity is not provided. Go to No.2.
• PoEStatus indicates denied
A shortage of electricity to the whole equipment occurs. Go to No.3.
• PoEStatus indicates faulty
Electricity is unable to be provided to the connected equipment. Go to No.4.
• The port is shutdown
Use the no shutdown command.
• The port is not showdown
Check to see if Power receiving equipment is connected properly.
3.
Troubleshooting Functional Failures in Operation
Action
"6.1 Testing
Line."
Action
35