Login From The Remote Operation Terminal Is Failed - NEC IP8800/S2400 Series Troubleshooting Manual

Nec electronics america network hardware user manual
Table of Contents

Advertisement

3.
Troubleshooting Functional Failures in Operation
Table 3-4: Problems and Actions When Connecting to Modem
No.
Failure
1
Automatic termination to the modem is
disabled.
2
Abnormal characters are displayed upon
login.
3
Line is busy and cannot be connected by
redialing after disconnection.
4
Line cannot be reconnected after line failure.
5
Line cannot be reconnected after
disconnection.
3.3.2

Login from the Remote Operation Terminal Is Failed

When connecting to the remote operation terminal fails, take actions in the following table.
Table 3-5: Problems and Actions When Connecting Remote Operation Terminal
No.
Symptom
1
Remote connection rejected.
2
Login rejected.
24
Check the following.
• Cable is connected properly.
• Modem is powered on.
• Telephone number is correct.
• Settings of the modem are correct.
• Line can be connected by connecting the modem to two terminals and
dialing.
Determine the cause by following the steps below:
1. Set the baud rate of the modem to 9600 bps.
2.
If the modem supports communication standard V90, K56flex, x2, or later,
set the modem so that it is connected via V.34 communication method or
below.
Termination may be disabled for several seconds after disconnection of the line.
See the manual provided with the modem.
When the line is disconnected due to a failure, reconnection may be disabled
for up to 120 seconds. If you want to connect the line immediately, login via
another method, and use the killuser command to apply forced logout to the
user who connected AUX by dial-up IP connection.
When dial-up IP connection is disconnected, it might take time to reconnect the
line. In this case, wait for approximately 30 seconds then reconnect the line.
Action to Be Taken or Reference
Determine the cause by following the steps below:
1. To make sure the route for the remote connection has been established, execute the
ping command from a PC or workstation.
2. After the message indicating the connection has been established is displayed, if it needs
much time to display the prompt, communication with the DNS server may possibly be
disabled. (If this is the case, it takes approximately five minutes until the prompt is
displayed, which is a typical value and usually depends on network conditions.)
Determine the cause by following the steps below:
1. Check to see if the terminal used has the IP or IPv6 address allowed by the access list
for the configuration command line vty mode. Furthermore, confirm that deny has
not been set for the IP or IPv6 address on the access list in the configuration command
(for details, see the manual "Configuration Commands, Vol. 1").
2. Confirm that maximum number of login users has not been exceeded (for details, see
the manual "Configuration Settings").
If reachability from the remote operation terminal to this system is lost when the
maximum number of users have logged in and then the reachability is recovered, a
remote operation terminal cannot log in to the system until the time of TCP protocol
timeout elapses to clear the session. The time of TCP protocol timeout is approximately
10 minutes although it depends on the states of the remote operation terminal and
network.
3. Check to see if protocols restricted by the configuration command transport
input in line vty mode are not being used. For more details, see the manual
"Configuration Commands."
Troubleshooting Steps