Manitowoc Indigo Series Technician's Handbook page 183

Hide thumbs Also See for Indigo Series:
Table of Contents

Advertisement

SYMPTOM
Alert icon on the display is flashing and the alert indicates
a T1, T2, T3, or T4 Fault.
CHECK PROCEDURE
Press the Menu button.
Scroll down to Service and press right arrow.
Scroll down to Diagnostics and press right arrow
Scroll down to Temp Sensors and press right arrow to
display thermistor temperature readings.
NOTE: An open thermistor will display -22°F (-30°C) and a
shorted thermistor displays 475°F (246°C).
Thermistor Test
1. Disconnect thermistor from control board and
measure resistance.
2. Measure temperature at the thermistor.
3. Compare measured resistance/temperature readings
to resistance/temperature relationship chart.
A.
Within 10% of the published resistance value -
Thermistor is good
B.
Not within 10% of the published resistance
value - Thermistor is defective.
Control Board Test
1. Disconnect thermistor from control board - The
display temperature reading, dropping to -22°F
(-30°C) indicates the control board is good.
2. Short thermistor pins - The display temperature
reading, climbing to 475°F (246°C) indicates the
control board is good.
Part Number STH026 6/15
183