Step 1
Open the front door to access the evaporator
compartment. Ice must not be on the evaporator during
the clean/sanitize cycle. Follow one of the methods
below:
•
Press the power switch at the end of a harvest cycle
after ice falls from the evaporator(s).
•
Press the power switch and allow the ice to melt.
Never use anything to force ice from the evaporator.
Damage may result.
Step 2
Remove all ice from the bin/dispenser.
Step 3
Press the clean switch. Water will flow through
the water dump valve and down the drain. Wait until the
water trough refills and the display indicates add solution
(approximately 1 minute), then add the proper amount of
ice machine cleaner.
Model
I0680/I0870/I0906CI1090/
I1200/IB0690C/IB0890C/
IB1090C
I1400/I1800/I2100
Part Number STH026 6/15
Caution
Amount of Cleaner
5 ounces (150 ml)
9 ounces (265 ml)
43