REPLACING PRESSURE CONTROLS WITHOUT
REMOVING REFRIGERANT CHARGE
This procedure reduces repair time and cost. Use it when
any of the following components require replacement,
and the refrigeration system is operational and leak-free.
Fan cycle control (air cooled only)
Water regulating valve (water cooled only)
High pressure cut-out control
Low Pressure cut-out control
High side service valve
Low side service valve
This is a required in-warranty repair procedure.
1. Disconnect power to the ice machine.
2. Follow all manufacturer's instructions supplied
with the pinch-off tool. Position the pinch-off tool
around the tubing as far from the pressure control as
feasible. (See the figure on next page.) Clamp down
on the tubing until the pinch-off is complete.
Do not unsolder a defective component. Cut it out
of the system. Do not remove the pinch-off tool until
the new component is securely in place.
206
Important
Warning
Part Number STH026 6/15