SYMPTOMS
Bin Switch Fails Open
G Model control boards or E Model control boards with
firmware version Rev.2.047 or higher.
The ice machine will not start an ice making cycle and
the display indicates "Full Bin".
The ice machine displays "Full Bin Remove Ice" in the
clean cycle.
E Control Boards with firmware versions prior to Rev.2.047
The ice machine will not start an ice making cycle and
the display indicates "Curtain Open".
The ice machine will run in the clean cycle.
Bin Switch Fails Closed
When running a "Long Harvest" alert is displayed and
safety limit 2 indicated.
May be off on a safety limit 2.
The harvest cycle continues after ice opens and closes
the ice damper (harvest cycle is 3.5 minutes).