Event Log - Manitowoc Indigo Series Technician's Handbook

Hide thumbs Also See for Indigo Series:
Table of Contents

Advertisement

EVENT LOG

Refer to the following table for Event Code descriptions.
Code
E01
Long Freeze Cycle
E02
Long Harvest Cycle
E03
Input Power Loss
E04
High Condenser Temperature
E05
High Pressure Control Opened
E06
Spare
E07
Starving TXV Single Evaporator or Low On Charge
E08
TXV Fault Single or Dual Circuit Evaporators
E09
Flooding Evaporator Fault Single Evaporator, Single
Circuit
E10
Flooding Evaporator Fault Dual TXV, Dual Circuit
E11
Refrigeration Fault
E12
Curtain Switch Fault - E Board = Open more than
12 hours, G Board after Revision 4.017 = Open more
than 24 hours
E13
Spare
E14
Spare
E15
Fan Cycle Control Fault - Lo Liquid Line Temperature
E16
Remote Condensing Unit Fault (ICVD Only)
E17
Spare
E18
Spare
E19
Ice Thickness Probe Fault
E20
Water System Fault
E21
T1 Temperature Sensor Issue
E22
T2 Temperature Sensor Issue
E23
T3 Temperature Sensor Issue
E24
T4 Temperature Sensor Issue
E25
Bin Level Probe Low Sensor Fault
E26
Bin Level Probe Medium Sensor Fault
E27
Bin Level Probe High Sensor Fault
E28
AuCS
E29
USB Communication Fault
E30
USB Download Fault
E31
Safe Mode
E32
RS485 Communication Fault
E33
KeyBoard Fault
E34
Display Fault
Part Number STH026 6/15