4.21 Setting the STEP PASS

Reducing this setting increases image quality by enabling smooth cutter-blade tip control when arcs are cut.
The STEP PASS setting specified is used as the unit for blade tip control, with blade tip control omitted for
any data below the STEP PASS setting. If the STEP PASS setting is too high, the image cut may not be
faithfully reproduced. Normally, the STEP PASS setting should be set to "1."
(1) Press the
C L E A R B U F F E R
(2) Press the
F E E D & C U T
B L A D E W A R E S E T U P
(3) Press the
P E N U P / D O W N
C U T L I N E P A T .
T A N G E N T I A L
I N I T . B
(4) Press the
P E N U P S P E E D
I N I T I A L F E E D
A U T O P R E F E E D
A D V A N C E D F U N C .
S E T U P M E N U
(5) Press the
T E S T
(PAUSE) key to switch to PAUSE mode.
(NEXT) or
A D V A N C E D F U N C .
(ENTER) key, and then press the
until the following menu is displayed.
S T E P P A S S
(ENTER) key to display the step-pass setting menu.
S T E P P A S S
Use the
or
key to select the required value within the range of "0" to
"20," and then press the
press the
(NEXT) or
(PAUSE) key to cancel PAUSE mode.
CHECKPOINT
This setting is retained in the internal memory even when the power is turned off.
(PREV.) key until the following menu is displayed.
1
(ENTER) key to confirm. To cancel the selection,
(PREV.) key.