Millivolt Board Removal / Installation - kozy heat 56101 'Windom" Installation And Operating Manual

Direct vent gas fireplace
Hide thumbs Also See for 56101 'Windom":
Table of Contents

Advertisement

MILLIVOLT BOARD REMOVAL / INSTALLATION

NOTE:
This unit is equipped with the millivolt board secured and log plate assembly already in position.
Follow these procedures should the millivolt board need replacing or is removed for servicing.
MILLIVOLT BOARD REMOVAL:
CAUTION: If the burner and/or pilot has been burning, the logs and refractory will be hot and will continue to
hold heat. Use the appropriate protection to avoid burns and place them on a properly protected surface upon
removal to avoid damage to flooring or personal property.
1. Turn the black control knob to the 'OFF' position.
2. Shut off the gas supply at the manual shut-off valve.
3. Disconnect gas line flex tube from the manual shut-off valve.
4. Disconnect any wall switch, remote control or thermostat wires from the top & bottom terminals on the gas
valve.
5. Remove the upper grill and glass assembly. Refer to the instructions in this manual if necessary.
6. Remove the 3 top logs, the 2 center logs, and the back log from the board and set aside on a properly
protected surface.
7. Remove the log plate by lifting it up and off the tabs (Figure 15A).
8. Remove the burner tube by lifting the front up and off the tabs, then slide it to the left, off the burner orifice.
FIGURE 15A
9. Loosen and remove the (6) nuts
securing the board (Figure 15B).
10. Carefully lift the board up off the
(6) mounting studs and remove
from the fireplace.
Log Plate
FIGURE 15B
Page 23
SECURED
WITH (6) NUTS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents