Cleaning & Maintenance Requirements - kozy heat SP-36 SLIM PROFILE 36"DIRECT VENT GAS FIREPLACE Installation & Operating Manual

Slim profile 36" direct vent gas fireplace
Table of Contents

Advertisement

(
M)
MAINTENANCE REQUIREMENTS
1.
The appliance should be inspected at least once a year
by a professional service person.
NOTE: INSTALLATION AND REPAIR SHOULD BE DONE
ONLY BY A QUALIFIED SERVICE PERSON. THE APPLIANCE
SHOULD BE INSPECTED BEFORE USE AND AT LEAST
ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE
FREQUENT CLEANING MAY BE REQUIRED DUE TO
EXCESSIVE LINT FROM CARPETING, BEDDING
MATERIALS, ETC. IT IS IMPERATIVE THAT CONTROL
COMPARTMENTS, BURNERS AND CIRCULATION AIR
PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
2.
The compartment below the firebox (behind the lower
grill) must be cleaned at least once a year, more frequent
cleaning may be required due to excessive lint from
carpeting, bedding materials, or other fibrous materials. It
is imperative that the burner be cleaned once a year.
FAN
The fan should be disconnected from electrical current, and
cleaned (vacuumed) every six months. The bearings are
sealed and require no oiling.
VENT SYSTEM
Annual examination of the venting system by a qualified
agency is required.
1.
Remove the upper grill & glass assembly.
2.
For easier access, remove the logs.
3.
Cover the millivolt board system.
4.
Loosen the nuts securing the baffle at the back of the
firebox and remove the baffle.
5.
Examine proper sealing of the vent system.
6.
Replace the baffle and secure the nuts - do not over-
tighten.
7.
Replace the logs, glass and upper grill.
IMPORTANT: ANY SAFETY SCREEN OR GUARD REMOVED
FOR SERVICING MUST BE REPLACED PRIOR TO
OPERATING THE APPLIANCE
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING ERRORS CAN
CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
MILLIVOLT BOARD SYSTEM
1.
Annual cleaning of the burner is required. The burner
tube / cover may be removed for easier access.
2.
Remove the logs.
3.
Remove the burner tube / cover by loosening the two
nuts securing it to the millivolt board. See page #24.
4.
Visually check for blocked port holes, especially near
the pilot. Blocked port holes may cause delayed
ignition.
5.
Visually check the pilot and burner flames when they
are burning. See Figures below. The flames should be
steady, not lifting or floating.
Burner Orifice
GLASS CLEANING & REPLACEMENT
C
Clean glass only when cool and only with non-abrasive
cleansers.
C
Do not operate this fireplace with the glass/frame
assembly removed, cracked or broken.
C
The glass assembly, Part #700-07T, shall only be
replaced as a complete unit, as supplied by Hussong
Mfg. Co., Inc.
C
Replacement of the glass & gasket assembly, Part
#700-07T, must only be performed by a licensed or
qualified service person.
MATERIALS.
C
Do not strike or slam glass door assembly.
CAUTION: KEEP THE APPLIANCE AREA CLEAR OF
COMBUSTIBLE MATERIALS, SUCH AS GASOLINE AND
OTHER FLAMMABLE VAPORS AND LIQUIDS.
Page 23
Honeywell Pilot
DO NOT SUBSTITUTE

Advertisement