Wall Switch - Thermostat - Remote Control Installation - kozy heat SP-36 SLIM PROFILE 36"DIRECT VENT GAS FIREPLACE Installation & Operating Manual

Slim profile 36" direct vent gas fireplace
Table of Contents

Advertisement

(J) THERMOSTAT - WALL SWITCH - REMOTE INSTALLATION
CAUTION: DO NOT CONNECT HIGH VOLTAGE (115V) WIRE TO THE GAS VALVE!
NOTE: INSTALLATION OF A THERMOSTAT OR WALL SWITCH
SHOULD ONLY BE DONE BY A QUALIFIED INSTALLER.
If desired, a thermostat (wireless style available),
wall switch, or remote control assembly may be
used to turn the fireplace 'OFF' and 'ON'. ONLY
one of these may be installed.
instructions included with each assembly.
NOTE: OPEN THE VALVE COVER TO EXPOSE
THE GAS VALVE AND WIRE CONNECTIONS ON
THE VALVE TERMINALS.
Disconnect the on/off rocker switch wires from
the top & bottom terminals on the gas valve.
REMOTE CONTROL USERS:
Follow instructions included with the remote
control.
IMPORTANT: The insulated cover included with
the remote control must be placed over the
remote receiver to protect it from overheating.
Remote Control Wiring Diagram
Figure 13
Follow
Thermostat Wiring Diagram
WALL SWITCH / THERMOSTAT USERS:
Run low-voltage (thermostat) wires from the
terminals on the gas valve to the desired location
of the wall switch or thermostat.
Attach the appropriate connector to each wall
switch / thermostat wire and connect to the top
and bottom terminals on the gas valve marked
'TH'.
Page 17
Figure 12

Advertisement

Table of Contents
loading