QUALIFIED
INSTALLER
Set-up Remote Control
The receiver and the handset of the remote control sys-
tem must be initially synchronized before the fi rst use.
1. Insert alkaline batteries in the remote control
receiver and handset. The receiver is located left
of the control valve under the burner module.
2. With a sharp object, press and hold the receiver's
reset button until you hear one short and one long
beeps. Release the reset button after the second
beep.
3. Within the subsequent 20 seconds, press the small
fl ame button (
) on the remote handset until you
hear two short beeps confi rming the synchronization
is set.
This is a one time setting only and is not required when
changing the batteries in the remote receiver. The
remote control system is now ready to use.
Check Operation
Turn the fi replace fl ame up and down using the
remote control to confi rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 10–14.
Set Aeration
Light the fi re and allow the unit to warm up for 10–15
minutes to evaluate the fl ame picture. Burners are
equipped with an adjustable shutter to control primary
aeration. See the fi gures below. The shutter is
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
Air Shutter
NG Air Shutter
Slider & Cover
36
Installation
NG
Close
Open
Close
Open
In a few unusual installations, the fl ame picture may
be improved by adjusting the aeration. The need for
adjustment should be determined only by operating the
appliance with the ceramic rocks and window installed.
Increasing aeration will cause the fl ames to appear
more transparent and blue showing more ceramic
effects glow.
Decreasing aeration will cause the fl ames to appear
more yellow or orange showing less ceramic effects glow.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.
Flashback
shield (for
LPG only)
LPG Air Shutter
Slider
LPG
Close
Open