Checking Pilot And Burner Flames; Using Handset Wall Holder - Valor PORTRAIT 530INI Installation & Owner's Manual

Direct vent gas insert fireplace
Hide thumbs Also See for PORTRAIT 530INI:
Table of Contents

Advertisement

4. Pull the top of the window forward
and release to ensure the springs
return it in position.
5. Similarly check the bottom of the
window by pulling it forward and
releasing.
6. Apply fi rm hand pressure around
the window frame to ensure the
window is sealed tight against the
fi rebox.
DANGER
!
The window unit must be correctly installed,
fastened and sealed after servicing or serious
bodily injury and/or damage to the appliance
may result.
To ensure a safe operation:
• Double-check that the bottom of the window
frame is correctly bolted at the bottom;
• Verify that the levers are hooked properly to
the window tabs then;
• Pull out the top and bottom of the window and
release it to insure the springs return it;
• Ensure the window is sealed before operation.
WARNING
!
Failure to install the window correctly can
leak carbon monoxide, affect the performance
of the fi replace, damage components, cause
overheating resulting in dangerous conditions.
Damage caused by incorrect window installa-
tion is not covered by the Valor warranty.
7. If the Hot Glass Warning plate has been removed
from the front lower corner of the window,
reinstall it by sliding it between the glass and
the frame as indicated.
Safety warning plate
Owner's Information
8. Reinstall the front and barrier screen.
F O R S A F E T Y P U R P O S E , ensure the
barrier screen is re-installed on the fi replace
front after maintenance.

Checking Pilot and Burner Flames

A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl ammable vapors and liquids. Inspect the vent terminal
outdoors regularly to make sure that dirt, snow, insects,
leaves, shrubs, trees do not obstruct it. Examine the
whole vent system regularly. We recommend annually.

Using Handset Wall Holder

Your fi replace equipment includes a wall
holder to store the handset. If it hasn't be
installed, refer to the instructions further
on in this manual for the installation.
WARNING
!
With Logs
With Rocks
Correct fl ame appearance
OWNER'S
INFORMATION
With Coals
Thermocouple
probe must be
in flame
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Portrait 530ipi

Table of Contents