Ensure base of heater is flush*
with finished hearth height,
otherwise front will not fit.
* Note: If installing
546 Ledgeview front,
4-sided frame drops 1-1/2"
below heater bottom.
530 insert engine with
standard co-linear vent
X
Dimensions
9" - 11-1/2"
depending on
front trim - see front
installation manual
2 x 3" dia.
colinear
vent
Cavity
Check that masonry step does not interfere with install dimensions
or vent pipe.
If mantel is combustible, see section Clearances for allowable
clearances.
Minimum width of fi replace opening at front: 20-1/2" (521 mm)
X = 9"–11-1/2" (229–292 mm)—varies with front trim options
Y = 25-1/2" (648 mm)
Y
Note: Using 546 Ledgeview front requires additional
1-1/2" (38 mm) cavity height.
20"
See Front trims installation
manuals for dimensions
4-3/4"x 3" dia.
co-axial adaptor
530 insert engine with optional
530CVA co-axial vent adapter
QUALIFIED
INSTALLER
21