Subaru EX13 Service Manual page 75

Hide thumbs Also See for EX13:
Table of Contents

Advertisement

Problem and check item
1. Checking of
Check S terminal and B terminal
continuity of
for deformation, looseness,
wiring
rusting, or dust sticking.
Carefully check inserting
method of the S terminal.
If not abnormal, set the key
switch to START position while
cranking (no ignition of engine)
and check if voltage is applied
to the S terminal and B terminal
of starter motor.
2. Battery checking Check battery voltage and specific
gravity of battery fluid.
[Voltage]
Normal value : 12.4 to 12.8V
Limit (charging required): 12.4V
or lower
Staring limit
[Specific gravity]
Normal value : 1.22 to 1.29
Limit (Charging required)
[Service life]
Variance in specific gravity
among cell
3. Checking of
Check if the pinion operates or
pinion operation
sound of magnetic switch
contactor is heard.
If the pinion does not operate
or magnetic switch sound is not
heard, check continuity of each
coil of magnetic switch.
(1) Operate the magnetic switch
4. Checking of
magnetic
and check B-M terminals
switch
(2) Check the magnetic switch
plunger and bobbin interior for
dust sticking or rusting.
5. Motor checking
Connect the (+) side of the
battery to the M terminal of
magnetic switch and check if the
motor runs.
Description
(+)
(-)
: 12V (at 20゚C)
: 1.22 or lower
: 0.04 or more
(+)
(-)
- 72 -
(1) When no voltage is applied to the S
terminal and B terminal, check
KEY SWITCH
continuity of the terminals and key
switch and repair or replace if
necessary.
S
B
(2) If voltage is applied to the S terminal
and B terminal, go to "2. Battery
K
checking."
M
(1) Charge or change the battery when
voltage is lower than 12.4V or specific
gravity is lower than 1.22 (at 20° C).
(2) If the wiring and battery are normal,
remove the star ter and go to "3.
GRAVITY METER
Checking of pinion operation."
BATTERY
(1) If the pinion operates or contactor sound
is heard, step to "4. Checking of
magnetic switch (1)."
(2) In case of no continuity
Replace the magnetic switch.
(3) When continuity is OK
Step to "4. Checking of magnetic switch
(2)."
(1) In case of no continuity
Contact continuity failure. Replace the
magnetic switch.
(2) When continuity is OK
Step to "5. Motor checking."
(1) Clean the plunger. If the bobbin interior
is contaminated, replace the magnetic
switch.
(1) If the motor does not run, check electric
circuit inside the motor, field coil,
armature, and brush and replace faulty
parts.
M
Remedy