Step
Parts to remove
Stop switch
4
Recoil starter
5
Blower housing
Baffle 2 (head)
Baffle 3
6
M4 TAPPING SCREW : 2 pcs.
BAFFLE 3
(EX21 ONLY)
M5 TAPPING BOLT : 2 pcs.
Remarks and procedures
Disconnect the wire and remove the stop
switch from the blower housing.
Remove the recoil starter from the blower
housing.
(1)Remove the blower housing from the
crankcase.
(2)Remove the baffle 2 (head) and baffle 3.
STOP SWITCH
BAFFLE 2 (HEAD)
M6 x 12 BOLT : 1 pc.
Fig. 5-4
- 17 -
10 mm box spanner
M6 × 8mm : 4 pcs.
10 mm box spanner
M6 × 12mm : 4 pcs.
10 mm box spanner or
spanner
M6 × 12mm : 2 pcs.
(Baffle 2 (head))
M5 tapping bolt : 2 pcs.
(Baffle 3)
M6 x 8 BOLT : 4 pcs.
M6 x 12 BOLT : 4 pcs.
BLOWER HOUSING
Fasteners
RECOIL STARTER