Step
Parts to remove
Electric starter (option)
Control box,
Diode rectifier,
15
Magnetic switch
ELECTRIC STARTER
(option)
Remarks and procedures
(1) Disconnect the grounding cable from battery.
(2) Disconnect the wire leading from the key
switch"ST" terminal to the magnetic switch.
(3) Disconnect the wire that connects the
positive terminal of the battery to the
magnetic switch.
(4) Remove the electric starter.
M6 NUT : 1 pc. (EX17,21)
M8 NUT : 1 pc. (EX27)
Fig. 5-8
- 21 -
Fasteners
12 mm box spanner
M8 nuts
10 mm box spanner
12 mm box spanner
EX27
M8 x 28 BOLT : 2 pcs.
EX17, 21
UPPER SIDE
M6 x 30 FLANGE BOLT : 1 pc.
DOWN SIDE
M6 x 20 FLANGE BOLT : 1 pc.