Mitsubishi Heavy Industries FDTC50ZHXV Technical Manual page 68

Hide thumbs Also See for FDTC50ZHXV:
Table of Contents

Advertisement

(b)Twin type
Model FDUM100VNPV(Indoor unit: 2 units, Outdoor unit: 1 units)
Item
Nominal cooling capacity
(1)
Nominal heating capacity
(1)
Power source
Cooling power consumption
Running current (Cooling)
Power factor (Cooling)
Heating power consumption
Running current (Heating)
Power factor (Heating)
Inrush current (L.R.A) <Max. running current>
Noise level
Exterior dimensions
Height × Width × Depth
Net weight
Refrigerant equipment
Compressor type & Q'ty
Starting method
Heat exchanger
Refrigerant control
Refrigerant
Quantity
Refrigerant oil
Defrost control
Air handling equipment
Fan type & Q'ty
Motor
Starting method
Air flow (Standard)
Available static pressure
Outside air intake
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Safety equipment
Installation data
Refrigerant piping size
Connecting method
Drain hose
Insulation for piping
Accessories
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
ISO-T1 "UNITARY AIR-CONDITIONERS"
(3) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.
(4) Values in [ ~
(5) Indoor unit specifications show the specifications for one unit. Capacity and running characteristics values are shown for the case where two indoor
units are combined and run together.
(6) Branching pipe set "DIS-WA1"×1 (option). ①:Pipe of O/U~Branch, ②:Pipe of Branch~I/U
(7) See page 77(1)~(4) for RANGE OF USAGE & LIMITATIONS.
Model
kW
kW
kW
A
%
kW
A
%
A
dB(A)
mm
kg
kg
r
W
CMM
Pa
W
Wired remote control switch (Optional : RC-E3)
Liquid line
mm
(in)
Gas line
Connectable with VP20 (I.D. 20mm, O.D. 26mm)
Indoor air temperature
Item
DB
27˚C
20˚C
] show the minimum to maximum range.
FDUM50V
1 Phase, 220-240V 50Hz/220V 60Hz
Hi:34 Me:31 Lo:28
299 × 750 × 635
34
Louver fin & inner grooved tubing
Microcomputer controlled de-icer
Centrifugal fan × 2
60 × 1
Direct line start
Hi: 14 Me: 12 Lo: 11
Standard: 50/40, Max 85/90
Possible
Procure locally
Rubber sleeve (for fan motor)
Wireless kit (Optional : RCN-KIT3-E)
Thermostat by electronics
Internal thermostat for fan motor.
Frost protection thermostat.
I/UΦ6.35(1/4") ②Φ9.52(3/8")×0.8 ①Φ9.52(3/8")×0.8 O/UΦ9.52(3/8")
I/UΦ12.7(1/2") ②Φ12.7(1/2")×0.8 ①Φ15.88(5/8")×1.0 O/UΦ15.88(5/8")
Necessary (both Liquid & Gas lines)
WB
19˚C
35˚C
7˚C
67
-
-
FDUM100VNPV
FDC100VN
10.0 [4.0~11.2]
11.2 [4.0~12.5]
3.12/3.12
13.6/14.3
99/99
3.27/3.27
14.3/15.0
99/99
5 <24>
845 × 970 × 370
RMT5126MDE2 × 1
Direct line start
Straight fin & inner grooved tubing
Electronic expansion valve
R410A
3.8 [Pre-charged up to the piping length of 30m]
0.9 (M-MA68)
Propeller fan × 1
86 × 1
Direct line start
Cooling type: 75, Heating type: 73
Rubber sleeve (for compressor)
20 (Crank case heater)
– (Indoor unit side)
Internal thermostat for fan motor.
Anomalous discharge temperature protection.
Flare piping
Holes size φ20 × 3 pcs
Drain hose
Filter kit (UM-FL1E)
Outdoor air temperature
DB
WB
24˚C
6˚C
49
74
Standards
ISO-T1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents