Mitsubishi Heavy Industries FDTC50ZHXV Technical Manual page 23

Hide thumbs Also See for FDTC50ZHXV:
Table of Contents

Advertisement

(b) Twin type
Model FDT71VNPV (Indoor unit: 2 units, Outdoor unit: 1 unit)
Item
Nominal cooling capacity
(1)
Nominal heating capacity
(1)
Power source
Cooling power consumption
Running current (Cooling)
Power factor (Cooling)
Heating power consumption
Running current (Heating)
Power factor (Heating)
Inrush current (L.R.A) <Max. running current>
Noise level
Exterior dimensions
Height × Width × Depth
Net weight
Refrigerant equipment
Compressor type & Q'ty
Starting method
Heat exchanger
Refrigerant control
Refrigerant
Quantity
Refrigerant oil
Defrost control
Air handling equipment
Fan type & Q'ty
Motor
Starting method
Air flow
Outside air intake
Air f ilter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Safety equipment
Installation data
Refrigerant piping size
Connecting method
Drain hose
Insulation for piping
Accessories
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. ISO-T1 "UNITARY AIR-CONDITIONERS"
(3) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.
(4) Values in [ ~ ] show the minimum to maximum range.
(5) Indoor unit specifications show the specifications for one unit. Capacity and running characteristics values are shown for the case where two indoor
units are combined and run together.
(6) Branching pipe set "DIS-WA1"×1 (option). ①:Pipe of O/U~Branch, ②:Pipe of Branch~I/U
(7) See page 35(1)~(4) for RANGE OF USAGE & LIMITATIONS.
Model
kW
kW
kW
A
%
kW
A
%
A
dB(A)
mm
kg
kg
r
W
CMM
W
Wired remote control switch (Optional : RC-E3)
Liquid line
mm
(in)
Gas line
Connectable with VP20 (I.D. 20mm, O.D. 26mm)
Indoor air temperature
Item
DB
27˚C
20˚C
FDT40V
1 Phase, 220-240V 50Hz/220V 60Hz
Hi:33 Me:31 Lo:30
Unit 246 × 840 × 840
Panel 35 × 950 × 950
27.5 (Unit:22 Panel:5.5)
Louver f in & inner grooved tubing
Microcomputer controlled de-icer
Turbo fan × 1
50 × 1
Hi:18 Me:16 Lo:14
Possible
Pocket plastic net × 1 (washable)
Rubber sleeve (for fan motor)
Wireless kit (Optional : RCN-T-36W-E)
Thermostat by electronics
Overload protection for fan motor.
Frost protection thermostat.
I/UΦ6.35(1/4") ②Φ9.52(3/8")×0.8 ①Φ9.52(3/8")×0.8 O/UΦ9.52(3/8")
I/UΦ12.7(1/2") ②Φ12.7(1/2")×0.8 ①Φ15.88(5/8")×1.0 O/UΦ15.88(5/8")
Necessary (both Liquid & Gas lines)
Mounting kit. Drain hose
Decorative Panel (T-PSA-36W-E)
WB
19˚C
22
-
-
FDT71VNPV
FDC71VN
7.1[3.2~8.0]
8.0[3.6~9.0]
1.85/1.85
8.0/8.6
99/98
1.99/1.99
8.7/9.1
99/99
5 <17>
750 × 968 × 340
2YC45DXD × 1
Direct line start
Straight f in & inner grooved tubing
Electronic expansion valve
R410A
2.95 [Pre-charged up to the piping length of 30m]
0.65 (FVC50K)
Propeller fan × 1
Direct line start
Cooling:60 Heating:50
Rubber sleeve (for compressor)
20 (Crank case heater)
– (Indoor unit side)
Internal thermostat for fan motor.
Anomalous discharge temperature protection.
Flare piping
Holes size φ20 × 3 pcs
Outdoor air temperature
DB
WB
35˚C
24˚C
7˚C
6˚C
48
60
86 × 1
Standards
ISO-T1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents