Power source
1~220-240V 50Hz/1~220V 60Hz
TB
F(30A)
F(8A)
L1i
RD
L1
WH
Noise filter
N
Ni
PWB3
L1o
GN
DM
+
P1
Inverter
PWB2
I P M
U
V
W
P2
V
W
+
U
MS
A/F Module
3~
CM
Meaning of marks
Marks
Parts name
CnA~Z
Connector
CH
Crankcase heater
CM
Compressor motor
Current sensor
CT
Diode module
DM
F
Fuse
FM01
Fan motor
IPM
Intelligent power module
Reactor
L
1
2
E
GN
E1
GN
No
CT
-
CNW2
N1
CNW
(OR)
(BK)
BL
CNI1
CNI2
(WH)
(WH)
CNI4
BL
CNI3
(WH)
(WH)
CNACT1
N2
P
N2
(WH)
RD
BL
CNA2
-
(WH)
RD
P
+
CNA1
BL
N2
(WH)
L1 L2
L
Mark
Parts mame
LED1
Indication lamp (GREEN)
LED2
Indication lamp (RED)
LPT
Low pressure sensor
Expansion valve for cooling
SM1
Expansion valve for heating
SM2
SW1
Pump down switch
SW3, 5
Local setting switch
TB
Terminal block
Thermistor (Ambient air temp.)
THo-A
TB
RD
1
WH
To indoor u'nit
2
3
Power wires
1
2
Signal wire
3
SM1
SM2
M
6
5
4 3
2
1
6
5
4
CNEEV1
CNEEV2
(WH)
Control
PWB1
ON
52X1
52X3
OFF
LED1
LED2
CNR
CNS
CNH
CNTH
(WH)
(RD)
(BR)
(WH)
CH
20S
63H1
THo-R1
THo-D
THo-S
THo-A
Mark
Parts mame
THo-D
Thermistor (Discharge pipe temp.)
THo-IPM
Thermistor (IPM)
THo-R1, 2
Thermistor (Heat exchanger pipe temp.)
Thermistor (Suction pipe temp.)
THo-S
Solenoid valve for 4 way valve
20S
52X1
Auxilliary relay (for CH)
52X3
Auxilliary relay (for 20S)
63H1
High pressure switch
FMO1
M
M
3
2
1
7
6
5 4 1
CNFAN1
(RD)
(WH)
ON
OFF
1
2
3
4
1 2
3
4
SW1
SW3
SW5
CNIP
CNPS
CNB
(Y)
(WH)
(RD)
LPT
THo-IPM
THo-R2
Color marks
Mark
BK
Black
BL
Blue
BR
Brown
Green
GN
GR
Gray
P
Pink
OR
Orange
RD
Red
White
WH
Yellow
Y
Yellow/Green
Y/GN
Color

Hide quick links: