Fujitsu Primergy RX100 S2 User Manual page 210

Table of Contents

Advertisement

Chapter 8 Hardware Configuration/Utilities
Item
Mode
Timeout Value
ASR&R Boot Delay (min)
Power Cycle Delay
Boot Retry Counter
Diagnostic System
Next Boot uses
Diagnostic PXE boot
device
Critical Temperature
Monitoring
Clear Screen Delay (sec)
IPMI
CPU Status
Memory Status
Console Redirection
210
table: Items on the Server Menu
Setting
• Continue (at the time of
purchase)
• Reset
• Power Cycle
• 0 (at the time of
purchase)
• 1–100
• 2 (at the time of
purchase)
• 1–30
10 (Fixed parameter)
• 0
• 1
• 2
• 3 (at the time of
purchase)
• 4
• 5
• 6
• 7
Disabled (Fixed parameter)
Boot Option (Fixed
parameter)
0 (Fixed parameter)
• Disabled (at the time of
purchase)
• Enabled
• 5 (at the time of
purchase)
• 0–31
[Enter]
[Enter]
[Enter]
[Enter]
Description
Sets the operation to be performed when a timeout
occurs during OS boot monitoring.
• Continue: The boot sequence is continued.
• Reset: The server restarts automatically and
starts POST.
• Power Cycle: The server turns off automatically.
The server turns on automatically after the time
specified in [Power cycle Delay].
When [O/S Boot Timeout] is set to [Enabled], the
system restarts automatically if the OS fails to start
up within the time set for this item.
Sets the standby time for startup after shutdown due
to trouble (such as overheating) in minutes. The
system restarts after the set standby time.
Sets the time until the server is turned on after it is
turned off.
Sets the maximum number of attempts to boot the
OS within the range of 0 to 7.
Sets the operation to be performed when the
number of system boot retries exceeds the number
specified in [Boot Retry Counter].
Specifies how to boot the system at the next startup.
This value can be selected when [Diagnostic
System] is set to [LAN] or [Remote Image Disk].
The server does not support this.
Sets whether or not to turn the power off in the
event of abnormal temperature.
Sets the time (seconds) during which the last BIOS
message screen is displayed before the OS starts up.
Configures the Baseboard Management Controller
(BMC).
"8.2.12 IPMI Submenu" (pg.211)
Displays whether or not to allow the use of the
installed CPU.
"8.2.13 CPU Status Submenu" (pg.212)
Sets whether or not to allow the use of the installed
memory.
"8.2.14 Memory Status Submenu" (pg.213)
Configures detailed settings for console redirection.
"8.2.15 Console Redirection Submenu" (pg.214)

Advertisement

Table of Contents
loading

Table of Contents