Mitsubishi Heavy Industries FDC112KXEN6 Technical Manual page 78

Table of Contents

Advertisement

Connector for branching
controller of heat recovery
3-pipe systems
Power source line
between indoor units
CNU
BL
Power source
(Single-phase)
220-240V~50Hz
TB1
220V~60Hz
L
RD
Power source
F(3.15A)
line
N
WH
F(3.15A)
Y/GN
Earth
Meaning of marks
CFI1,2
Capacitor for FMI
CNA~Z
Connector
Drain motor
DM
Fuse
F
Fan motor (with thermostat)
FMI1,2
Float switch
FS
Live Superlink terminal setting
JSL1
(for spare)
LED . 2
Indication lamp
(Green-Normal operation)
LED . 3
Indication lamp (Red-Inspection)
SM
Stepping motor
(for electronic expansion valve)
SW1
Indoor unit address : tens place
Indoor unit address : ones place
SW2
Outdoor unit address : tens place
SW3
SW4
Outdoor unit address : ones place
ThI-R1
ThI-R2
ThI-R3
t .
t .
t .
Control PCB
1
2
3
4
5
CNN
Y
RD
3
WH
1
CNW0
X6
X2
RD
X1
X3
1
3
5
7
9
C
UH
H
M
L
F(0.16A)
5
5
CNF3
CNF4
WH
5
5
WH
Y/GN
Y/GN
M
M
1~
1~
FMI1
CFI1
CFI2
SW5-1
Automatic adjustment/Fixed previous
version of Superlink protocol
Indoor unit address : hundreds place
SW5-2
Model capacity setting
SW6
Operation check, Drain motor
SW7-1
test run
Terminal block (Power source)
TB1
(□ mark)
Terminal block (Signal line) (□ mark)
TB2
Thermistor (Remote controller)
Thc
Thermistor (Return air)
ThI-A
Thermistor (Heat exchanger)
ThI-R1,2,3
Thermistor
TrI
X1~3,6
Relay for FM
Relay for DM
X4
Closed-end connector
mark
ThI-A
Tr
I
t .
220-240V
19V
24V
6
1
2
CNW1
CNW2
CNH
WH
BK
BK
SW1
SW2
SW5
X4
SW6
SW3
SW4
SW7
CNA
CNI
RD
CNR
BL
1
3
1
2
3
4
5
6
WH
M
CNRI
WH
SM
M
1~
FS
DM
Color marks
Mark
Color
BK
Black
BL
Blue
BR
Brown
GR
Gray
OR
Orange
RD
Red
WH
White
Y
Yellow
Y/GN
Yellow/Green
Notes
1.
indicates wiring on site.
2.Use twin core cord (0.75~1.25mm
outdoor unit, and signal line between indoor units.
3.Use twin core cord (0.3mm
controller in case that the total length is more than 100m.
4.Do not put signal line and remote controller line alongside power source line.
Option
+12
1
2
XR1
3
XR2
CNT
LED • 2
BL
4
XR3
JSL1
5
XR4
Superlink (spare)
6
LED • 3
XR5 (Remote operation input:
CNK2
volt-free contact)
BK
+12
1
2
XB1
CNT2
3
XB2
RD
CNB
CNK1
4
XB3
WH
WH
5
XB4
1
3
1
2
For Heat recovery
3-pipe systems
X
Y
A
B
TB2
X
X
Y
Y
Signal line (Shielded cord)
Remote
controller
.
Signal line
t
Thc
between indoor units
2
) at signal line between indoor unit and
2
) at remote controller line. See spec sheet of remote
(Operation)
(Heating)
(Thermo ON)
(Inspection)
(20S)
(SVH)
(SVG)
(SVE)