Mitsubishi Heavy Industries FDC112KXEN6 Technical Manual page 38

Table of Contents

Advertisement

Models FDE112KXE6, 140KXE6
Item
1
Nominal cooling capacity*
2
Nominal heating capacity*
Power source
Noise level
Exterior dimensions
Height
Width
Depth
Net weight
Refrigerant equipment
Heat exchanger
Refrigerant control
Air handling equipment
Fan type & Q'ty
Motor
Starting method
Air flow(Standard)
Outside air intake
Air filter, Q'ty
Shock & vibration isolator
Insulation (noise & heat)
Operation control
Operation switch
Room temperature control
Safety equipment
Installation data
Refrigerant piping size
Connecting method
Drain hose
Insulation for piping
Accessories
Optional parts
Notes
(1) The data are measured at the following conditions.
Item
Operation
1
Cooling*
2
Heating*
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
ISO-T1 "UNITARY AIR-CONDITIONERS"
Models
FDE112KXE6
kW
kW
dB(A)
Hi: 44 Me: 41 Lo: 39
mm
kg
W
CMM
Hi: 26 Me: 23 Lo: 21
mm(in)
Indoor air temperature
DB
WB
27
19
20
-
11.2
12.5
1 Phase 220-240V 50Hz/220V 60Hz
250
1620
46
Louver fin & inner grooved tubing
Electronic Expansion Valve
Centrifugal fan 4
30 2
Direct line starting
Not possible
Pocket plastic net
Rubber sleeve(for fan motor)
Polyurethane foam
Wired remote control switch (Optional:RC-E3)
Wireless kit (Optional:RCN-KIT3-E)
Thermostat by electronics
Internal thermostat for fan motor.
Frost protection thermostat
Liquid line: 9.52(3/8"), Gas line: 15.88(5/8")
Flare piping
Connectable with VP20(I.D.20mm, O.D.26mm)
Necessary (both Liquid & Gas lines)
Mounting kit, Drain hose
_
Outdoor air temperature
DB
35
7
34
-
FDE140KXE6
14.0
16.0
Hi: 46 Me: 44 Lo: 43
690
40 2
Hi: 29 Me: 26 Lo: 23
2(Washable)
Standards
WB
24
ISO-T1
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents