Mitsubishi Heavy Industries FDC112KXEN6 Technical Manual page 72

Table of Contents

Advertisement

Connector for branching
controller of heat recovery
Power source line
3-pipe systems
between indoor units
Power source
(Single-phase)
220-240V~50Hz
TB1
220V~60Hz
RD
L
Power source
RD
F(3.15A)
line
WH
N
WH
F(3.15A)
CNW0
RD
Y/GN
Earth
Color marks
Mark
Color
BK
Black
BL
Blue
BR
Brown
GR
Gray
LB
Light Blue
LG
Light Green
OR
Orange
P
Pink
RD
Red
WH
White
FMI1
Y
Yellow
Y/GN
Yellow/Green
Meaning of marks
CFI1
Capacitor for FMI
Connector
CNA~Z
Drain motor
DM
F
Fuse
Fan motor (with thermostat)
FMI1
Float switch
FS
Live Superlink terminal setting (for spare)
JSL1
LED . 2
Indication lamp (Green-Normal operation)
LED . 3
Indication lamp (Red-Inspection)
LM
Louver motor
LS
Louver switch
SW1
SW2
SW3 SW4
SW5
CNL6
SM
WH
M
1
2
3
4
5
6
7
8
9
1011
CNU
BL
1 2 3 4 5 6
CNL5
CNL1
CNL2
CNL4
CNL3
RD
BK
BK
BL
WH
BK
CNA
3
X4
1
X6
X2
X1
X3
CNJ2
CNR
1
3
5
7
9
WH
1
3
C
UH
H
M
L
CNM3
WH
F(0.16A)
CNR2
BL
CNF1
WH
5
M
1~
M
DM
1~
CFI1
SM
Stepping motor
(for electronic expansion valve)
Indoor unit address : tens place
SW1
Indoor unit address : ones place
SW2
Outdoor unit address : tens place
SW3
Outdoor unit address : ones place
SW4
SW5-1
Automatic adjustment/Fixed previous
version of Superlink protocol
SW5-2
Indoor unit address : hundreds place
Model capacity setting
SW6
Operation check, Drain motor test run
SW7-1
ThI-R1
ThI-R2
t .
t .
Tr
I
CNA2
WH
220-240V
CNN2
BK
19V
24V
1
2
3
CNW1
CNW2
BK
WH
LED • 2 LED • 3
SW6
Superlink (spare)
X5
SW7
CNB
CNS
CNI
WH
BL
1
3
1
3
BL
BL
CNI2
WH
CNJS
WH
CNS3
X Y
TB2
WH
FS
LS
X Y
M
1~
Remote
controller
t .
LM
Thc
TB1
Terminal block (Power source)(□ mark)
Terminal block (Signal line) (□ mark)
TB2
Thermistor (Remote controller)
Thc
Thermistor (Return air)
ThI-A
Thermistor (Heat exchanger)
ThI-R1,2,3
Thermistor
TrI
X1~3,6
Relay for FM
Relay for DM
X4
X5
Relay for LM
mark
Closed-end connector
ThI-R3
ThI-A
t .
t .
4
5
6
1
2
CNH
BK
CNN
Y
Option
+12
1
JSL1
XR1
2
3
CNT
XR2
BL
CNK2
4
XR3
BK
5
XR4
CNK1
6
WH
XR5 (Remote operation input:
1
2
volt-free contact)
For Heat recovery
3-pipe systems
+12
1
2
XB1
CNT2
3
XB2
RD
4
XB3
XB4
5
A B
Control PCB
Signal line (Shielded cord)
Signal line
between indoor units
Notes
1.
indicates wiring on site.
2.Use twin core cord (0.75~1.25mm
line between indoor unit and outdoor unit, and
signal line between indoor units.
2
3.Use twin core cord (0.3mm
) at remote
controller line. See spec sheet of remote
controller in case that the total length is more
than 100m.
4.Do not put signal line and remote controller line
alongside power source line.
(Operation)
(Heating)
(Thermo ON)
(Inspection)
(20S)
(SVH)
(SVG)
(SVE)
2
) at signal