INSTALLATION INSTRUCTIONS
Connect to the electricity supply
Warning: This appliance must be
earthed.
The appliance must be installed by a
competent electrician using a double
pole control unit of 32 ampere minimum
capacity with 3mm minimum contact
separation at all poles.
We recommend that the appliance is
connected by a qualified electrician
who is a member of the N.I.C.E.I.C.
and who will comply with the I.E.E.
and local regulation.
1. Access to the mains terminal is
gained by opening the terminal
block cover at the rear of the
appliance (use a small flat-bladed
screwdriver).
2. Connection should be made with
6.0mm
flexible twin and earth
2
cable.
3. First strip the wires, then push the
cable through the cable clamp in
the terminal block cover.
4. Connect the cable to the terminal
block using an 8mm socket and
tighten the cable clamp screw (see
diagram).
5. Close the terminal box, ensuring
that the cover is engaged on the
locking tabs.