Main Error Codes, Possible Causes And Solutions - Drolet Eco-65 DP00060 Installation And Operation Manual

Hide thumbs Also See for Eco-65 DP00060:
Table of Contents

Advertisement

Eco-65 Installation and Operation Manual

8.3 Main Error Codes, Possible Causes and Solutions

WARNING: RISK OF ELECTRICAL SHOCK. IF YOU NEED TO MANUALLY TEST, MANIPULATE OR
REPLACE ANY COMPONENTS, THE STOVE NEEDS TO BE DISCONNECTED FROM THE WALL OUTLET.
This section contains main error codes, possible causes and many suggestions to guide you
in resolving them. After giving an error code, your stove will shut down by itself and start a
cool down cycle. If you want to start your stove again, you will need to press on the
button and then on the
completed.
NOTE: IF, AFTER PERFORMING ALL THE POSSIBLE SOLUTIONS MENTIONED IN THE FOLLOWING
SECTION, YOU ARE STILL EXPERIENCING PROBLEMS WITH YOUR STOVE, CALL YOUR LOCAL
DEALER OR A SERVICE TECHNICIAN AT 418-908-8002. YOU CAN ALSO WRITE AN EMAIL TO
tech@sbi-international.com. ALL EMAILS ARE ANSWERED WITHIN A 24H DELAY.
NOTE: IF YOU NEED TO CONTACT YOUR DEALER OR TECHNICAL SUPPORT, MAKE SURE TO HAVE
THE MODEL OF YOUR STOVE AND THE SERIAL NUMBER ON HAND. (THEY CAN BE FOUND ON THE
CERTIFICATION LABEL INSIDE THE HOPPER LID).
MESSAGE
Pressure switch warning.
Warning caused by the automatic L-250 sensors: it is located over the pellet
housing.
Hopper is empty
Lighting warning.
Hopper lid stayed open more than 3 minutes.
Inverted polarity in power outlet.
Power outage
Igniter fuse is blown
Auger fuse has blown
50
button. Your stove will only restart when the cool down cycle is
ALARM CODES CHART