Installation Configurations; Installation Warnings, Cautions And Recommendations Reminder - Drolet Eco-65 DP00060 Installation And Operation Manual

Hide thumbs Also See for Eco-65 DP00060:
Table of Contents

Advertisement

Eco-65 Installation and Operation Manual
Canada:
Min.
Letter
clearances
A
12'' (30 cm)
B
39'' (100 cm)
F
39'' (100 cm)
H
39'' (100 cm)
I
72'' (183 cm)
J
39'' (100 cm)
K
72'' (183 cm)
L
84'' (213 cm)
39'' (100 cm)
United States:
• Not Less than 36'' (91 cm) above any forced air inlet located within 10 feet (305 cm);
• Not Less than 48'' (122 cm) below and horizontally from, or one foot (30 cm) above, any
door, window or gravity air inlet into any building;
• Not Less than 24'' (61 cm) from an adjacent building and not less than 84'' (213 cm)
above grade when located adjacent to a public walkway.
• Cannot be located less than 12 inches (300mm) above grade.
• Cannot be located above a gas meter/regulator within 3 feet (900mm) horizontally of the
vertical center line of the regulator.
• Not within 6 feet (1.8 meters) of a gas service regulator vent outlet.
• Other restrictions may apply. See NFPA 211 for further information.

4.5 Installation Configurations

4.5.1 Installation Warnings, Cautions and Recommendations Reminder

• PROFESSIONNAL INSTALLATION IS HIGHLY RECOMMENDED
• THIS STOVE USES A PRESSURIZED VENTING SYSTEM. ALL VENT CONNECTOR
JOINTS MUST BE SEALED AND FASTENED. CONSULT THE PELLET VENT
MANUFACTURER'S
CONSISTENT PERFORMANCE, AND TO AVOID SMOKE AND ASH SPILLAGE.
Clearances above grade level or any adjacent surface that might
support snow, ice, or debris
Clearance to window or door that may be opened
Clearance to corner or adjacent wall
Not to be installed above a meter/regulator assembly within 39" (100
cm) horizontally from the vertical center-line of the regulator and for 15'
vertically
Clearance to gas service regulator vent outlet or within 39'' (100 cm) of
an oil tank vent or an oil tank fill inlet
Clearance to the combustion air inlet to any other appliance
Clearance to a mechanical air supply inlet
Clearance above paved side-walk or a paved driveway located on
public property
Clearance to property boundary
A vent shall not terminate underneath a veranda, porch, or deck
INSTRUCTION
Description
TO
ENSURE
PROPER
INSTALLATION,
17