General Features - Drolet Eco-65 DP00060 Installation And Operation Manual

Hide thumbs Also See for Eco-65 DP00060:
Table of Contents

Advertisement

Eco-65 Installation and Operation Manual

1.3 General Features

Recommended chimney diameter
Flue outlet diameter
Type of chimney
Baffle material
Approved for alcove installation
Approved for mobile home
installation
Shipping weight (without option)
Appliance weight (without option)
Type of door
Glass type
Blower
Particulate emission standard
USA standard (safety)
Canadian standard (safety)
Noise level at 6 feet
Electrical requirements
Control board fuses
Mobile home (Canada) or manufactured home (USA): The US department of Housing and Urban
Development describes "manufactured homes" better known as "mobile homes" as followed; buildings
built on fixed wheels and those transported on temporary wheels/axles and set on a permanent
foundation. In Canada, a mobile home is a dwelling for which the manufacture and assembly of each
component is completed or substantially completed prior to being moved to a site for installation on a
foundation and connection to service facilities and which conforms to the CAN/CSA-Z240 MH standard.
4 po (see Section 4.3: Equivalent Vent Length
(EVL))
4 po (100 mm)
ULC/ORD-C441, CAN/ULC S609, UL 641 (TYPE L)
Stainless Steel
Not approved
Yes
440 lb (200 kg)
371 lb (168 kg)
Single, glass with cast iron frame
Ceramic glass
Included (up to 500 CFM)
EPA / CSA B415.1-10
ASTM E1509 and UL 1482
ULC S627
Min: 53 dBa (+/- 3 dBa) − Max: 59 dBa (+/- 3 dBa)
Voltage and frequency: 120VAC and 60Hz
AC Current: 2.15A/120VAC - 3.7A/120VAC
-Main: 7.5A-250V fast-blow fuse
-Convection blower: 5A-250V fast-blow fuse
-Combustion blower: 3A-250V fast-blow fuse
-Exhaust blower: 3A-250V fast-blow fuse
-Auger motor #1: 3A-250V fast-blow fuse
-Auger motor #2: 3A-250V fast-blow fuse
-Igniter: 5A-250V fast-blow fuse