8.3.1 P Code

STOVE SHUTS OFF AND
Possible Causes:
1. Pressure tap (located on the
exhaust blower) is blocked.
2. The flue is blocked or needs
cleaning.
3. The flue is not properly installed.
4. A back draft occurred inside the
flue.
5. The
pressure
connections are faulty.
6. The pressure switch hose is
disconnected.
7. The
exhaust
blower failed.
APPEARS ON CONTROL BOARD
Possible
possible)
Pull off the air hose from the exhaust blower pressure
tap and from the negative (white) pressure switch tap.
WARNING: THE TUBE MUST ABSOLUTELY BE
DISCONNECTED FROM THE PRESSURE SWITCH
AS TO NOT DAMAGE IT.. Blow in the air tube. If air
flows freely, the hose is fine. If air does not flow
through the hose, use a thin wire to clear the blockage.
One of the following components is obstructed or
blocked by ashes of by a foreign object; air intake
shutter, combustion blower, burn pot, heat exchangers
and exhaust channels, exhaust blower and or venting
system. Refer to the maintenance section.
Make sure the venting system meets the criteria in the
installation section of this manual as well as the
venting system manufacturer's instructions.
This can occur on a very windy day or if your venting
system does not have a proper termination.
switch
wire
Make sure that the pressure switch wires and
connections are not grounded or loose. Replace or
replug wires if necessary.
Make sure the pressure switch hose is well installed on
the exhaust blower pressure tap and on the white (-)
pressure switch tap. If not, reinstall it.
or
combustion
See Section 8.2: Testing a Component and test the
exhaust and the combustion blowers independently. If
one of them does not work, make sure there is power
and that blowers are well connected. If they still don't
work, check fuse F4 and F5 on the control board. A
defective fuse will be darkened or will have a broken
filament. If the fuses are good, the combustion or
exhaust blower is probably defective. Replace the
faulty part.