8.3.5 d Code
STOVE STOPS FEEDING PELLETS AND
Possible Cause:
1. The hopper lid has stayed open for more
than 3 minutes.
2. The hopper lid safety switch is faulty or
disconnected.

8.3.6 N Code

THE STOVE FUNCTIONS BUT DISPLAYS WARNING CODE
Possible Cause:
1. A reversed polarity is detected on the
electrical outlet or on the same electrical
circuit.
2. No ground is detected or connected in the
wall outlet.

8.3.7 C Code

THE STOVE FUNCTIONS BUT DISPLAYS WARNING CODE
Possibles Cause:
Warning generated by a power failure
while the stove was running.
APPEARS ON THE CONTROL BOARD
Possible Remedy:
As a security measure, the auger stops
turning and feeding pellets as soon as the
hopper lid opens. It will resume normal
operation as soon as the hopper lid is closed.
If the hopper lid stays open for more than 3
minutes, the stove will stop.
Make sure that the switch wiring is properly
connected. If it is, the hopper switch may be
faulty
(see
Component) and verify the proper function of
the safety switch. Replace it if necessary.
Possible Remedy:
Test and ensure the proper connections.
Test and ensure the proper connections of
the electrical wires and/or correct the grounds
of the unit.
Possible Remedy :
The stove will restart on the initial setting once it
cools off.
Note: For a short power failure (less than 5
seconds), the stove will continue to function at the
selected speed.