8.3.2 H Code

STOVE STOPS FEEDING PELLETS AND
BEFORE RESETTING TAKE CARE IN READING THE POSSIBLE CAUSES AND THEN
PRESS ON
Possible Cause:
1. Inadequate fuel is used.
2. The flue is not properly installed.
3. The flue is blocked or needs cleaning.
4. The stove needs maintenance.
5. The burn pot is not installed properly.
6. The baffle is not installed properly or holes
may be blocked.
7. The convection blower is defective.
8. he combustion blower needs cleaning.
9. The exhaust blower is defective.
AND
AT THE SAME TIME FOR 2 SECONDS.
APPEARS ON THE CONTROL BOARD.
Possible Remedy:
Remove the burn pot, make sure that all
openings are clear and check that no ash has
filled the tube around the igniter. Refer to the
maintenance section. Also, make sure that
the recommended fuel is used (see Section
4.8.1: Proper Fuel).
Make sure the venting system meets the
criteria in the Section 4: Venting System as
well as the venting system manufacturer's
instructions.
One
of
the
following
obstructed or blocked; air intake shutter,
combustion
blower,
exchangers and channels, exhaust blower
and or venting system. Refer to Section 7:
Maintenance.
Refer to Section 7: Maintenance.
Make sure the burn pot is installed correctly
(see Section 7.1.4: Cleaning the Burn Pot).
Make sure the baffle is well installed and the
lock is in place. Make sure the holes are clear
(see Section 7.1.2: Cleaning the Baffle, the
Heat Exchanger and the Combustion
Chamber).
See Section 8.2: Testing a Component and
test the convection blower.
Carefully clean blower housing and make
sure blower louvers are not blocked.
See Section 8.2: Testing a Component and
test the exhaust blower.
components
is
burn
pot,
heat
53