IP-PTs with a single line display (e.g., KX-NT265)
To start programming
Supply power to the IP-PT.
To set the IP address of the IP-PT
VOL
Press VOLUME to
Press SP-PHONE.
select "Network".
Press SP-PHONE.
To set the subnet mask address
VOL
Press VOLUME to
select "Subnet Mask".
To set the default gateway address (if required)
VOL
Press VOLUME to
select "Default GW".
To enter the IP address of the IP-EXT card (PBX IP Address)
HOLD
Press HOLD
Press VOLUME
twice to return
to select "PBX".
to the Menu screen.
To set VLAN parameters
To the VLAN settings
OR
To end programming
Press STORE.
*1 Valid IP address range: "1.0.0.0" to "223.255.255.255"
*2 Valid IP address range: "0.0.0.0" to "255.255.255.255"
*3 Valid IP address range: "1.0.0.0" to "223.255.255.255"
PROG.
Press PROGRAM
while "Searching" is displayed. .
VOL
Press VOLUME to
select "DHCP (Disable)".
Subnet Mask Address*
Press SP-PHONE.
Default Gateway Address*
Press SP-PHONE.
VOL
Press SP-PHONE
twice.
The IP-PT will reboot
and establish connection
to the network.
4.2 Programming the IP Proprietary Telephone
Press SP-PHONE
twice.
2
Press SP-PHONE.
3
Press SP-PHONE.
PBX IP
1
Address*
Press SP-PHONE.
Information about IP Proprietary Telephones
1
IP Address*
HOLD
Press HOLD
to return to the
Menu screen.
37