8.5.3 "Contact" operating mode settings

48
Settings
Batch
Auxiliary freq.
Calibrate
Dosing
Relay
The operating mode
mode - see the following chapter. Here also, you can select a number of
strokes (no fractions, only integers from 1 to 99,999).
Operating mode
Metering can be triggered by pressing the
received via the "External Control" terminal.
The number of received pulses, which could not yet be processed, is
stored by the pump in the stroke memory, if it was activated.
CAUTION!
When changing over from the "Manual" operating mode to
the "Batch" operating mode, the pump maintains the stroke
rate.
The stroke rate can also be set in 'Batch' mode. It should
normally be set to the maximum stroke rate.
Additionally, you can activate the "Memory" function extension (Identifier
"m"). When "Memory" is activated, the pump adds up the remaining
strokes , which could not be processed, up to the maximum capacity of the
stroke memory of 99,999 strokes. If this maximum capacity is exceeded,
the pump goes into fault mode.
The
'Contact' menu is available under 'Contact' mode in the 'Settings'
menu.
'Contact' operating mode allows you to trigger individual strokes or a
stroke series.
You can trigger the strokes via a pulse sent via the "External control" ter‐
minal.
The purpose of this operating mode is to convert the incoming pulses with
a reduction (fractions) or small step-up into strokes.
Batch
Memory
Factor
5
End
Batch
Memory
Factor
5
End
'Batch' is one variant of the 'Contact' operating
'Batch' is intended for large metering quantities.
[P/OK] key or via a pulse
Memory
Off
On
Factor
0 0 0 0 5