DA 40 AFM
After Climbing to a Height From Which the Selected Landing Area Can Be Reached Safely:
4. Fuel tank selector . . . . . . . . . . . . . . . . . . . . OFF
5. Electrical fuel pump . . . . . . . . . . . . . . . . . . . OFF
6. Cabin heat . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
%
7. Master switch (ALT/BAT) . . . . . . . . . . . . . . . OFF
8. Emergency window(s) . . . . . . . . . . . . . . . . . open if required
9. Carry out emergency landing with engine off. Allow for increased landing
distance due to the flap position.
In case of extreme smoke development, the front canopy may
be unlatched during flight. This allows it to partially open, in
order to improve ventilation. The canopy will remain open in
this position. Flight characteristics will not be affected
significantly.
END OF CHECKLIST
Doc. # 6.01.01-E
CAUTION
Rev. 8
01-Dec-2010
Emergency
Procedures