7.15 CO-MONITOR (IF INSTALLED)
%
%
The airplane may be equipped with a CO detector (OÄM 40-253).
%
7.15.1 SELF TEST SEQUENCE
%
When power is applied to the CO detector, a self-test routine begins. The test checks
%
for functionality of the critical components such as the CO sensor, temperature sensor,
%
and the integrity of the total CO detector system.
%
The remote alert light will flash twice. Then the remote light will remain OFF until there
%
is another CO alert or until a failure of the unit occurs.
%
7.15.2 IN-FLIGHT CO ALARM
%
If the CO detector visual alert annunciator illuminates in flight, press the TEST/RESET
%
button.
%
If the alert continues with the remote light staying ON, proceed with the emergency
%
procedure 3.7.3 - SUSPICION OF CARBON MONOXIDE CONTAMINATION IN THE
%
CABIN.
%
%
The remote light will stay on until the CO level goes below
%
50 PPM.