Diamond DA 40 Flight Manual page 134

Table of Contents

Advertisement

Normal Operating
Procedures
When Engine Fires:
7. Mixture control lever . . . . . . . . . . . . . . . . . . rapidly move to RICH
8. Oil pressure . . . . . . . . . . . . . . . . . . . . . . . . . green sector within 15 sec
If the oil pressure has not moved into the green sector within
15 seconds after starting, SWITCH OFF ENGINE and
investigate problem.
9. Master switch (ALT) . . . . . . . . . . . . . . . . . . . ON
10. Ammeter . . . . . . . . . . . . . . . . . . . . . . . . . . . check
11. Fuel pressure . . . . . . . . . . . . . . . . . . . . . . . . check (14 PSI to 35 PSI)
12. Annunciator panel . . . . . . . . . . . . . . . . . . . . check
END OF CHECKLIST
Page 4A - 18
WARNING
Rev. 8
01-Dec-2010
DA 40 AFM
Doc. # 6.01.01-E