Component Testing; Ignition Switch - Toro 30821 Service Manual

Hide thumbs Also See for 30821:
Table of Contents

Advertisement

Component Testing

For accurate resistance and/or continuity checks, elec-
trically disconnect the component being tested from the
circuit (e.g. unplug the ignition switch connector before
doing a continuity check on the switch).
NOTE: For more component testing information, see
the Kubota Workshop Manual, Diesel Engine, 05 Se-
ries.

Ignition Switch

The ignition (key) switch has three positions (OFF, ON/
PREHEAT, and START). The terminals are marked as
shown. The circuitry of the ignition switch is shown in the
chart below. With the use of a multimeter (ohms setting),
the switch functions may be tested to determine whether
continuity exists between the various terminals for each
position. Verify continuity between switch terminals.
SWITCH
NORMAL
POSITION
CIRCUITS
OFF
NONE
ON/PREHEAT
B + A + I
START
B + S + I
Groundsmaster 3500- D
When testing electrical components for continu-
ity with a multimeter (ohms setting), make sure
that power to the circuit has been disconnected.
OTHER
CIRCUITS
NONE
X + Y
NONE
1. Switch
2. Key
Page 5 - 9
CAUTION
A
Y
B
S
I
X
Figure 4
3
1
4
Figure 5
3. Hex nut
4. Lock washer
OFF
45 
Figure 6
Electrical System (Rev. G)
2
ON/PREHEAT
45 
START